Magnetic Pump CQB : The CQB magnetic drive pump is a new type of
completely leak-free corrosion-resistant pump developed by the
National Joint Design Group of Magnetic Pumps. Its technical and
economic indicators are equivalent to those of similar foreign
products in the late 1980s. It is a supplement and improvement to
the CQ pump. Main features: an ideal pump for leak-free transport
all kinds of corrosive media.The optimized product jointly designed
by the national magnetic pump can directly replace the ih type
chemical process pump. Application :petroleum, chemical,
metallurgy, pharmaceutical, electroplating, environmental
protection, and other industries, and can transport flammable,
explosive, highly toxic, and precious liquids below 100°C. Using
the principle of magnetic transmission, no leakagePump Body :The
flow part of the pump is made of all stainless steel, which has
good corrosion resistance to organic acids, organic compounds,
alkali, neutral solutions, and a variety of gases. The double
spiral groove carbon graphite bearings and cemented carbide
bushings Run-in, with strong wear resistance, to ensure the life of
the product.Condition : Since the cooling and
lubrication of the magnetic pump bearing depends on the conveyed
medium, idling rotation is prohibited, and at the same time,
avoiding idling operation caused by restarting after a power cut in
the middle of the work. If the conveyed medium contains solid
particles, a filter should be added to the pump inlet: if it
contains ferromagnetic particles, a magnetic filter should be
added. The ambient temperature of the CQB magnetic drive
centrifugal pump during use should be less than 40ºC, and the
temperature rise of the motor should not exceed 75ºC. The conveyed
medium and its temperature should be within the allowable range of
the pump material (see attached table for details). The service
temperature of the engineering plastic pump is less than 60ºC, the
service temperature of the metal pump is less than 100ºC, the
conveying suction pressure is not more than 0.2mpa, the working
pressure is 1.6mpa, the density is not more than 1600kg/m3, and the
particle size is not more than 30 × 10-6m2/s. Liquid without hard
particles and fibers.the medium that is easy to precipitate and
crystallize as the conveying liquid, it should be cleaned in time
after use, and the liquid accumulated in the pump should be
drained. the CQB magnetic pump has been running for 100 hours, the
wear of the bearing and the end face moving ring should be
disassembled and inspected, and the wearing parts that are not
suitable for reuse should be replaced. The internal and external
magnetic couplings of CQB-type magnetic drive pumps adopt
high-performance permanent magnet materials, which may cause
potential harm to the following devices. Please keep the following
devices away from this series of pumps. Such as cardiac pacemakers,
credit cards, and other magnetic cards, calculators, computer
disks, watches, etc.Technical Parameter : Flow Up to
100m3/hHead Up to 80 mSpeed 2900 RPMPower Up to 55 kWInner Caliber
Up to 100 mmOuter Caliber Up to 65 mm Troubleshooting
:FaultCauseMethod of exclusionno water comes out of the
Pump 1- the water pump reverses 2- Air leakage
in the water inlet pipe 3-The voltage is too high, and the coupling
slips when starting. 4- the suction lift is too high.5-the
suction lift is too high.6-the valve does not open.1-change the
motor wiring.2-Prevent air leakage.3-Increase the water
storage.4-Adjust the positive voltage.5-lower the sand installation
position.6-correct or change the valve.Insufficient flow1-the
suction pipe diameter is too small or blocked. 2- the
impeller flow passage is blocked.3-the head is too high.4-the speed
is not enough.1-change the inlet pipe.2-clean the impeller.3-open
the large water outlet valve.4-recover the rated speed. Head
is too low 1-the flow is too large.2- the speed is too
low.1-close the small water outlet valve.2-recover the rated
speed. Too noisy1- the shaft is severely worn.2- the
shaft sleeve is severely worn.3- Drive the magnetic steel cup
in contact with the isolating sleeve.4-Grinding of the seal ring
and impeller.1-replace the pump shaft.2-replace the shaft
sleeve.3-Remove the pump head and reassemble it.4-Replace thrust
ring and seal ring.Leakage1- The sealing ring is
damaged.1- Replace the o-shaped sealing ring.Borra Technology
Co., Ltd.Borra Technology co., Ltd., founded in 1995, owns a
top-rank design, production, sales, and service team, and modern
production lines, to manufacture various self-priming pumps,
movable diesel pumps, diesel Self-Priming dirt drain pumps, diesel
fire pumps units, diesel mini-pumps.Certificate :Services:1. One
year or 1000 working hours guarantee of the whole machine except
for wear parts;2. Technical support by email the whole day;3.
Calling service;4. User's manual available;5. Installation guide
for clients from both China and abroad;6. Maintenance and
replacement service;
Related products about Magnetic Pump, Horizontal Vertical Water Pump
- Waste Tyre Plastic Recycling Machinery Machine Tire Crusher Production Line Rubber Crumb Grinding Machine Equipment Tire Shredder
- Stretch Plastic Blowing Pet Bottle Making Blow Molding Machine Bottles Stretch Automatic Pet Bottle Blowing Machine
- Waste Plastic Pet Bottle, Water Bottle Flake, PP/HDPE/LDPE PE Film Jumbo Woven Bags Plastic Crusher Machine, Plastic Crushing Washing Recycling Machine
- Type 2 Wall-Mounted Electric Car Charging Station 7kw /11 Kwelectric Vehicle Charging Station Home Wallbox AC EV Charger Single Phase or 3three Phase
- G-View G12W Wholesale Auto Car LED Headlight Bulb High Power H13 H11 9005 H7 H4 Car LED Headlights LED Car Lights
- New Design Porcelain Round Plates Dinner Set for Wedding and Banquet
- China 2023 New Design Super Soft 100% Polyester Microfiber Knitted Oversized Decoration Hoodie Blanket
- Handmade Art Creative Materials Thickened White Paper Cup DIY Disposable Handmade Colored Paper Cup