Xbc Model Diesel Engine Horizontal Fire Water Pump

XBC model diesel engine water pump,diesel water pumpDiesel Engine Driven Fire PumpWe are specializing in the production of pump more than 50 years1.Q: 6.3-400M3/H2.H:5-125M3. Speed: 1450 r/mSpecificationsWith stable performance and high efficiency, it mainly used for water works, irrigation, drainage station, power station, air-conditioner circling water supply, industry, fire-protection water supply, ship industry, oil industry and other situations which need to transport water like liquid.With volute structure, it has big flow capacity and high head.XBC series horizontal single-stage firefighting pump the max working pressure is 1.6Mpa, it means suction pressure with head no more than 1.6Mpa.transport medium similar with water.environmental temperature no more than 40 degrees, the height above sea level no more than 1000meters. And the humidity no more than 95%.it is single-stage pump, mainly used for booster water supply and fire fighting equipments or similar situations.  fault phenomenonfailure causeelimination methods 1.No power supply or one or two phase power supply is needed Check all phases of power supply and restore power supply   2.Poor contact of ac contactor and burning of coil Repair or replace contactors  can not start3.The power switch is not closed, malfunction or damaged  Close the switch and replace it if the power indicator does not turn on 4.Thermal relay trip or damage  Check whether the motor is blocked, find out the reason and eliminate it.Manual reset is replaced if it cannot be started Water level is too low Put water in the sink   The motor burned Repair or replace the motor   1.Line is loose Check wiring and tighten connectors   2.Frequency converter malfunctionCheck the fault content, check the cause according to the frequency converter manual, and restart after reset.Or disconnect the inverter power supply for a few seconds, the inverter fault reset before starting.The manual is normal3The frequency converter is damagedRepair or replaceAutomatic transmission failure4.Pressure switch damageRepair or replace 5The pressure transmitter is damagedRepair or replace 6.Switch failureRepair or replacePump non - suction pressure gauge pointer to beat violentlyInsufficient water supply for perfusion, air leakage at the connection between pipeline and instrumentCheck pipeline and bottom valve, refill water diversion. Tighten air leakage The pump consumes too much power   Too much flow, impeller wear  Check whether the pump shaft is bent, replace the impeller, close the outlet valve to reduce the flow  ESTABLISHED IN THE SIXTIES♦ ONE OF THE FIRST THROUGH THE ISO9001:2008 DOMESTIC, INTERNATIONAL QUALITY SYSTEM CERTIFICATION ♦ SILVER MEDAL WAS AWARDED AT THE NATIONAL CONFERENCE ON THE APPLICATION OF SPARK CUP TECHNOLOGY ♦ WIN THE NATIONAL AWARD FOR EXCELLENCE IN CIVILIZATION COMPETITION  ♦ GET THE LC OF THE CHINESE GOVERNMENT /* March 10, 2023 17:59:20 */!function(){function s(e,r){var a,o={};try{e&&e.split(",").forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1