2023 Dry Fluid Cooler for Industrial Power Cooling Injection Moulding Machines Cooling

Dry Fluid Cooler for industrial power cooling, injection moulding machines cooling Dry Fluid Cooler FeaturesUnique floating coil design avoids leakage caused by thermal expansion and contraction. Staggered fin pattern design and corrugated fin enhance air flow turbulence Inner-grooved copper tube increase heat transfer area and enhance heat transfer Optimized flow pass design ensure fully heat exchange with refrigerant Equipped with 2nd generation owl-wing fan motor as standard. It features with low noise level, large volume flow and low energy consumption. Ready for dual speed connection. Outdoor type powder coated casing made of galvanized sheet metal and stainless steel bolts provide a high resistance to corrosion. Optional features: EC variable speed fan motor, to save great energy ZAplus/AxiTop for greater volume flow and extreme silence Adiabatic system significantly reduce energy consumption in summer Epoxy coated or hydrophilic aluminum fin suitable for coastal or high corrosion area Fluid dry cooler Clean stainless steel tube and aluminum fin coil for cooling deionized water. Dry Fluid Cooler Product showing Dry Fluid Cooler specificationDry Fluid Cooler FeaturesHigh efficiency heat exchanger: capacity designs for maximizing the heat transfer relative to the energy consumption of the fan. Tube and tube coupling design for low pressure drop in the coil on the media sides(maximum 100KPa at water designing condition). Our thermodynamic and aerodynamic designing software is long year tested and proved in GermanyFan: only choose low specific energy consumption fans. Fan nozzle designs for maximum air flow and air throw.Our fans from the world`s leading manufacturer are practically proved to be reliable in operation and long lasting. Motor: protection class IP 54 and insulation class F. Air separator for each fan.We facilitate you to have a long lasting and low maintenance operation. Durable material and rigid enclosure with hard gloss powder coated finish. Protective enclosure for both manifolds and U-bends. Unit design for outdoor installation. 100% leakage tested at 31bar.  Dry Fluid Cooler options1. Coil design refrigerant: water, oil, glycol. Multiple circuits.Sub-cooling circuits.Stainless steel or aluminum casing.Coated aluminum or copper fins.Explosion ploof motor.Customized fin spacing.  fluid cooler Application:Industrial field: process engineering, heat / power plant, power generation, chemical industry, air conditioning chiller, heat transformer, smelting, etc.. It is suitable for all equipment which needs heat dissipation and is installed in the open air.     fluid cooler Technical parameter:Dry cooler D2 series parameter(fin space 2.1mm) TypeD2-148-4x630D2-166-4x630D2-175-4x630D2-228-6x630D2-250-6x630D2-276-6x630D2-310-8x630D2-343-8x630D2-364-8x630D2-392-10x630CapacityWaterKW147.99165.85175.21227.85250.42276.53309.85342.73364.07391.9920% Et. GlycolKW142.42161.57170.91219.09244.69270.22301.18333.55354.64383.3Air flowM3/h764597434172134114686111511108188152911148675144255191136FanNo. X φ2x2x6302x2x6302x2x6302x3x6302x3x6302x3x6302x4x6302x4x6302x4x6302x5x630Fan motor400/3N/50HZA20.420.420.430.630.630.640.840.840.851.00Sound pressure leveldB(A)10m64646466666667676768DimensionLmm2186218621863250325032504250425042505250Hmm1874187418741874187418741874187418741874Dmm2100210021002100210021002100210021002100D1mm2000200020002000200020002000200020002000L1mm963963963963963963963963963963L2mm1000100010001000100010001000100010001000L3mm1963196319632963296329633963396339634963Connections inlet φmm2XDN502XDN652XDN652XDN652XDN802XDN802XDN802XDN802XDN1002XDN100Connections onlet φmm2XDN502XDN652XDN652XDN652XDN802XDN802XDN802XDN802XDN1002XDN100Product weight(empty)kg7698118531134119712611498158916731864  fluid cooler pictures:fluid cooler package  /* March 10, 2023 17:59:20 */!function(){function s(e,r){var a,o={};try{e&&e.split(",").forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1