Stack Flue Gas Analyzer Cems for Nox So2 O2 CO2 Co Vocs Basic Customization Sample Customization

Stack Flue Gas Analyzer CEMS for Nox So2 O2 CO2 Co Vocs Introduction:WT800-VOCs volatile organic compounds online monitoring system has three basic parts: the volatile organic compounds monitoring subsystem, flue gas parameter monitoring subsystem, system control and data acquisition and processing subsystem. It can monitor organic pollutant gases such as methane, the total hydrocarbon, non methane total hydrocarbon, low-carbon aldehyde ketone, benzene series(benzene, toluene, xylene, ethyl benzene, isopropyl benzene) and part of halogenated hydrocarbons, also the parameter such as humidity, temperature, pressure and flow velocity of the flue gas. After dedusting by sampling probe, sampling by heating pipe, dehydration and cooling by two-step condensing, the measured gas is analyzed by the heated gas anal-ysis module (GC-FID). For the situation of high boiling point organic pollutant gas monitoring, it can effectively avoid the absorption loss in the process of sample collection and transmission, alsomake sure the excellent performance and stability in sample collection, analysis, data upload and maintain links.Technical Features:·Gas Chromatography method defined as an international standard VOC measurement method;·Making use of the pneumatic constant temperature complies with regulations and this constant temperature from sampling to probe avoids water interference and reduces sample loss; ·Extremely wide range of measurement;·Sample directly at the probe;·Ability to measure hundreds of type of waste gas (e.g. NMHC, BTX and odours), the possibility to continuous extend the range and types of measurement;·Improving security by using FID and anti-explosion design.Application:Apply to manufacturing industry such as crude processing, textile and dyeing, chemical and pharmaceutical, metal smelting, etc.Technical Specifications:  ProjectDescriptionVOCs volatile organic compoundsMeasuring principlePrinciples of Gas ChromatographyMeasuring componentsMethane/Non-methane total hydrocarbons, benzene series(benzene toluene ),etc.Measuring range0-1000ppm(configurable)MethaneNMHCBenzene series0-1000ppm0-10000ppm0-1000ppmThe detection limitMethane 0.1ppmRepeatabilityRSD≤3%Measurement deviation≤2%FSAnalysis cycle1.5minResponse time90s(25m heating pipeline)Sampling pipelineHeating temperature above 125ºC IPC6 channels RS232/4854 USB portsWindows 7System softwareExhaust gas treatment VOCs online monitoring systemOutputAnalog output channelRS485 communication interfaceGPRS communication interfaceEthernet communication interfaceSystem status switch output(optional)Power supply220VAC/50Hz 2kW(host part, excluding heating pipe, air compressor)Cabinet size600mmx900mm×2055mCabinet temperature(5-35)ºCCabinet humidity(20%-90%)R  DetectorGas actionGas namePurityFIDCarrier gasHe or N2Not less than99.999%TCDCarrier gasHe,H2or N2Not less than99.999%ECDCarrier gasN2Not less than99.999%(deoxidation)FPDCarrier gasHe or N2Not less than99.999% Tail blowingHe or N2Not less than99.999% Combustion gasH2Not less than99.999% Auxiliary gasAirClean and dry as much as possible  /* March 10, 2023 17:59:20 */!function(){function s(e,r){var a,o={};try{e&&e.split(",").forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1