R32 Full DC Inverter A+++ Air Source Monoblock Heat Pump for
heating cooling and hot water Features Features:1.Hot
water up to 65ºC,suitable for underfloor/radiator heating/fan
coil2.can work stable at ambient temperature -25C to
45C3.E-Heater,diverter valve and water pump can be inclueded4. A+++
Energy Rating Level5.Full inverter system,Stable and efficient
performance.6.R32 System,environment friendly7.Application
Scope:Hotels,clubs,hospitals,villas and any place in need of air
conditioning,heating and hot water8.With Wifi App
controlInstallation Diagram Installation Diagram: Two
Heating circuits Technical Parameter Technical
Parameter:Market model WW08VWW10VWW12VWW14VMHeating1Output
CapacitykW3.40~8.653.70~10.304.95~12.465.92~14.94Input
Power kW0.59~1.650.62~2.050.90~2.481.15~3.20COP-5.23~5.725.02~5.905.03~5.504.67~5.12Input
CurrentA2.82~7.922.96~9.814.31~11.855.50~15.3Heating2Output
CapacitykW3.43~7.773.90~9.844.37~12.435.18~14.30Input
Power kW0.91~2.411.01~3.121.21~3.951.33~4.69COP-3.23~3.803.15~3.813.15~3.613.05~3.89Input
CurrentA2.56~11.524.83~14.935.78~18.896.36~22.45Heating3Output
CapacitykW4.11~10.375.10~13.256.25~14.637.52~16.57Input
Power kW0.74~2.280.94~13.731.14~3.121.37~3.56COP-4.55~5.564.61~5.424.69~5.464.66~5.47Input
CurrentA3.54~10.914.50~12.495.45~14.936.55~17.03Cooling4Output
CapacitykW3.04~7.573.82~8.215.05~11.456.02~12.31Input
Power kW0.94~2.751.18~3.021.54~4.131.87~4.53EER-2.75~3.232.72~3.252.77~3.282.73~3.22Input
CurrentA4.50~13.155.64~14.457.37~19.768.95~21.67Power
Supply V/PH/HZ220-240V/1/50HzErP
level(35ºC)-A+++A+++A+++A+++ErP level(55ºC)-A++A++A++A++Water Side
Heat Exchanger -Plate heat exchangerDisplay
controller -LCD touch screenBackup
heater (Optional) kW3kW Expansion
vessel/5LRefrigerant Type -R32Max Water Temperature(without
backup heater)ºC60Working Ambeint TemperatureºC-25~43Water
connection inchG1-1/4Sound pressure Level
@1m dB(A)50505253Net Dimension
(L*W*H) mm995*410*800995*410*8001065*410*9601065*410*960Market
model WW14VTWW16VWW18VWW20VWW22VHeating1Output
CapacitykW5.92~14.946.48~16.387.29~18.518.10~20.568.91~22.35Input
Power kW1.15~3.201.29~3.581.39~3.981.56~4.491.73~5.06COP-4.67~5.124.57~5.014.65~5.254.58~5.204.42~5.13Input
CurrentA2.05~5.712.31~6.412.49~7.122.79~8.033.09~9.06Heating2Output
CapacitykW5.18~14.305.93~16.586.67~18.657.41~20.688.15~21.15Input
Power kW1.33~4.691.39~5.631.58~6.431.77~7.181.97~7.50COP-3.05~3.892.94~4.262.90~4.222.88~4.182.82~4.13Input
CurrentA2.38~8.392.48~10.072.83~11.503.17~12.843.52~13.42Heating3Output
CapacitykW7.52~16.578.95~19.4210.07~21.8511.18~24.0512.30~25.5Input
Power kW1.37~3.561.62~4.211.84~4.772.08~5.312.33~5.73COP-4.66~5.474.61~5.524.58~5.464.53~5.384.45~5.28Input
CurrentA2.45~6.372.90~7.533.29~8.533.72~9.504.17~10.25Cooling4Output
CapacitykW6.02~12.317.23~14.828.13~15.729.03~16.679.93~17.50Input
Power kW1.87~4.532.27~5.432.64~5.863.00~6.363.35~6.78EER-2.73~3.222.73~3.182.68~3.082.62~3.012.58~2.96Input
CurrentA3.34~8.104.06~9.714.72~10.485.37~11.386.00~12.13Power
Supply V/PH/HZ380-415V/3/50HzErP
level(35ºC)-A+++A+++A+++A+++A+++ErP
level(55ºC)-A++A++A++A++A++Water Side Heat Exchanger -Plate
heat exchangerDisplay controller -LCD touch screenBackup
heater (Optional) kW3kW Expansion
vessel/5LRefrigerant Type -R32Max Water Temperature(without
backup heater)ºC60Working Ambeint TemperatureºC-25~43Water
connection inchG1-1/4Sound pressure Level
@1m dB(A)5356565858Net Dimension
(L*W*H) mm1065*410*9601065*410*9601150*430*13501150*430*13501150*430*1350Note:1.Outdoor
air temperature 7ºC DB,6ºC WB;EWT 30ºC,LWT 35ºC.2.Outdoor air
temperature 7ºC DB,6ºC WB;EWT 47ºC,LWT 55ºC.3.Outdoor air
temperature 20ºC DB,15ºC WB;EWT 15ºC,LWT 55ºC.4.Outdoor air
temperature 35ºC DB,24ºC WB;EWT 12ºC,LWT 7ºC.5.The Specifications
are subject to changes without notice. Key
Functions: R32 environmental refrigerant1. R32 has a GWP
of 675, roughly 30% lower than that of R410A2. R32 systems use up
to 20% less refrigerant than R410A, making them more efficient and
cost less to operate3. Ozone Depletion Potential of 04. Easier to
recycle than R410A, as R32 is a single component refrigerantDHW
tank disinfectionThe DHW tank disinfection function is used to kill
legionella by 65°C water to ensure the health and safety.Climate
curveYou can choose different climate correlation curves or your
own customised curve. Once the curve is selected, the unit sets the
outlet water temperature automatically according to the outdoor
ambient air temperature.Floor preheating and dryingProtect your
home floor by activating the Floor Preheating function
which slowly increases the heating temperature of the floor
coils, avoiding possible floor damaging and transitioning
smoothly to the heating function. The Floor Drying Up function
provides an additional solution to the installer as it helps
remove any residual moisture from newly installed floor coils,
further protecting the installation and ensuring the
optimal and effective operation of the heat pump.Powerful
heating with high
Related products about R32 Full DC Inverter a+++ Air Source Monoblock Heat Pump for Heating Cooling and Hot Water
- Waste Tyre Plastic Recycling Machinery Machine Tire Crusher Production Line Rubber Crumb Grinding Machine Equipment Tire Shredder
- Stretch Plastic Blowing Pet Bottle Making Blow Molding Machine Bottles Stretch Automatic Pet Bottle Blowing Machine
- Waste Plastic Pet Bottle, Water Bottle Flake, PP/HDPE/LDPE PE Film Jumbo Woven Bags Plastic Crusher Machine, Plastic Crushing Washing Recycling Machine
- Type 2 Wall-Mounted Electric Car Charging Station 7kw /11 Kwelectric Vehicle Charging Station Home Wallbox AC EV Charger Single Phase or 3three Phase
- G-View G12W Wholesale Auto Car LED Headlight Bulb High Power H13 H11 9005 H7 H4 Car LED Headlights LED Car Lights
- New Design Porcelain Round Plates Dinner Set for Wedding and Banquet
- China 2023 New Design Super Soft 100% Polyester Microfiber Knitted Oversized Decoration Hoodie Blanket
- Handmade Art Creative Materials Thickened White Paper Cup DIY Disposable Handmade Colored Paper Cup