8kw-24kw R32 Inverter a+++ Monoblock Heat Pump Water Heater Air Source Heat Pump for Heating Cooling and Hot Water

R32 Full DC Inverter A+++ Air Source Monoblock Heat Pump for heating cooling and hot water  FeaturesFeatures:1.Hot water up to 65ºC,suitable for underfloor/radiator heating/fan coil2.can work stable at ambient temperature -25C to 45C3.E-Heater,diverter valve and water pump can be inclueded4. A+++ Energy Rating Level5.Full inverter system,Stable and efficient performance.6.R32 System,environment friendly7.Application Scope:Hotels,clubs,hospitals,villas and any place in need of air conditioning,heating and hot water8.With Wifi App controlInstallation Diagram Installation Diagram:  Two Heating circuits   Technical Parameter Technical Parameter:  Market model WW08VWW10VWW12VWW14VMHeating1Output CapacitykW3.40~8.653.70~10.304.95~12.465.92~14.94Input Power kW0.59~1.650.62~2.050.90~2.481.15~3.20COP-5.23~5.725.02~5.905.03~5.504.67~5.12Input CurrentA2.82~7.922.96~9.814.31~11.855.50~15.3Heating2Output CapacitykW3.43~7.773.90~9.844.37~12.435.18~14.30Input Power kW0.91~2.411.01~3.121.21~3.951.33~4.69COP-3.23~3.803.15~3.813.15~3.613.05~3.89Input CurrentA2.56~11.524.83~14.935.78~18.896.36~22.45Heating3Output CapacitykW4.11~10.375.10~13.256.25~14.637.52~16.57Input Power kW0.74~2.280.94~13.731.14~3.121.37~3.56COP-4.55~5.564.61~5.424.69~5.464.66~5.47Input CurrentA3.54~10.914.50~12.495.45~14.936.55~17.03Cooling4Output CapacitykW3.04~7.573.82~8.215.05~11.456.02~12.31Input Power kW0.94~2.751.18~3.021.54~4.131.87~4.53EER-2.75~3.232.72~3.252.77~3.282.73~3.22Input CurrentA4.50~13.155.64~14.457.37~19.768.95~21.67Power Supply V/PH/HZ220-240V/1/50HzErP level(35ºC)-A+++A+++A+++A+++ErP level(55ºC)-A++A++A++A++Water Side Heat Exchanger -Plate heat exchangerDisplay controller -LCD touch screenBackup heater (Optional) kW3kW Expansion vessel/5LRefrigerant Type -R32Max Water Temperature(without backup heater)ºC60Working Ambeint TemperatureºC-25~43Water connection inchG1-1/4Sound pressure Level @1m dB(A)50505253Net Dimension (L*W*H) mm995*410*800995*410*8001065*410*9601065*410*960Market model WW14VTWW16VWW18VWW20VWW22VHeating1Output CapacitykW5.92~14.946.48~16.387.29~18.518.10~20.568.91~22.35Input Power kW1.15~3.201.29~3.581.39~3.981.56~4.491.73~5.06COP-4.67~5.124.57~5.014.65~5.254.58~5.204.42~5.13Input CurrentA2.05~5.712.31~6.412.49~7.122.79~8.033.09~9.06Heating2Output CapacitykW5.18~14.305.93~16.586.67~18.657.41~20.688.15~21.15Input Power kW1.33~4.691.39~5.631.58~6.431.77~7.181.97~7.50COP-3.05~3.892.94~4.262.90~4.222.88~4.182.82~4.13Input CurrentA2.38~8.392.48~10.072.83~11.503.17~12.843.52~13.42Heating3Output CapacitykW7.52~16.578.95~19.4210.07~21.8511.18~24.0512.30~25.5Input Power kW1.37~3.561.62~4.211.84~4.772.08~5.312.33~5.73COP-4.66~5.474.61~5.524.58~5.464.53~5.384.45~5.28Input CurrentA2.45~6.372.90~7.533.29~8.533.72~9.504.17~10.25Cooling4Output CapacitykW6.02~12.317.23~14.828.13~15.729.03~16.679.93~17.50Input Power kW1.87~4.532.27~5.432.64~5.863.00~6.363.35~6.78EER-2.73~3.222.73~3.182.68~3.082.62~3.012.58~2.96Input CurrentA3.34~8.104.06~9.714.72~10.485.37~11.386.00~12.13Power Supply V/PH/HZ380-415V/3/50HzErP level(35ºC)-A+++A+++A+++A+++A+++ErP level(55ºC)-A++A++A++A++A++Water Side Heat Exchanger -Plate heat exchangerDisplay controller -LCD touch screenBackup heater (Optional) kW3kW Expansion vessel/5LRefrigerant Type -R32Max Water Temperature(without backup heater)ºC60Working Ambeint TemperatureºC-25~43Water connection inchG1-1/4Sound pressure Level @1m dB(A)5356565858Net Dimension (L*W*H) mm1065*410*9601065*410*9601150*430*13501150*430*13501150*430*1350  Note:1.Outdoor air temperature 7ºC DB,6ºC WB;EWT 30ºC,LWT 35ºC.2.Outdoor air temperature 7ºC DB,6ºC WB;EWT 47ºC,LWT 55ºC.3.Outdoor air temperature 20ºC DB,15ºC WB;EWT 15ºC,LWT 55ºC.4.Outdoor air temperature 35ºC DB,24ºC WB;EWT 12ºC,LWT 7ºC.5.The Specifications are subject to changes without notice.  Key Functions: R32 environmental refrigerant1. R32 has a GWP of 675, roughly 30% lower than that of R410A2. R32 systems use up to 20% less refrigerant than R410A, making them more efficient and cost less to operate3. Ozone Depletion Potential of 04. Easier to recycle than R410A, as R32 is a single component refrigerantDHW tank disinfectionThe DHW tank disinfection function is used to kill legionella by 65°C water to ensure the health and safety.Climate curveYou can choose different climate correlation curves or your own customised curve. Once the curve is selected, the unit sets the outlet water temperature automatically according to the outdoor ambient air temperature.Floor preheating and dryingProtect your home floor by activating the Floor Preheating function which slowly increases the heating temperature of the floor coils, avoiding possible floor damaging and transitioning smoothly to the heating function. The Floor Drying Up function provides an additional solution to the installer as it helps remove any residual moisture from newly installed floor coils, further protecting the installation and ensuring the optimal and effective operation of the heat pump.Powerful heating with high