Split Warmepumpe Evi Inverter Air Source Heat Pump Water Heaters Hybrid 200L Heating All in One Heat Pump Air to Water 20kw

Full DC Inverter Evi cooling and heating heat pump of HEEALARX adopts Mistubishi twin rotary inverter type compressor, famous brand plate heater exchanger, panasonic dc inverter fan motor, can operate steadily in -35 centigrade low ambient temperature, for house heating, floor heating, cooling and also hot water for both house and office building.  R32  DC INVERTER AIR TO WATER HEAT-PUMP WITH TANK ModelVS90-DCT VS160-DCTVS220-DCT Power supply 220~240V,50Hz3/380~415V/50HZHot water(air+20ºC/water15-55ºC)CapacityKW8.00 13.00 15.0Heating water capacityKW2.21 3.61 4.18Heating(air+20ºC/water55ºC)CapacityKW9.50 16.20 19.80 Heating water capacityKW2,444.14 7.67 Rated current A10.69 6.29 5.06 COPW/W3.88 3.91 3.92 Heating(air+7ºC/water35ºC)CapacityKW9.015.018.00 Heating water capacityKW2.13 3.57 4.35 Rated current A9.35 5.61 6.70 COPW/W4.21 4.20 4.13 Heating(air+2ºC/water35ºC)CapacityKW8.50 14.516.95 Heating water capacityKW2.35 4.00 4.72 Rated current A10.32 6.12 7.25 COPW/W3.61 3.62 3.59 Heating(air0ºC/water35ºC)CapacityKW8.18 14.05 16.52 Heating water capacityKW2.46 4.18 5.00 Rated current A10.85 6.35 7.60 COPW/W3.32 3.36 3.30 Heating(air-5ºC/water35ºC)CapacityKW7.98 13.88 16.12 Heating water capacityKW2.64 4.56 5.35 Rated current A11.52 6.93 8.13 COPW/W3.02 3.04 3.01 Heating(air-7ºC/water35ºC)CapacityKW7.90 13.60 15.82 Heating water capacityKW2.73 4.78 5.60 Rated current A11.95 7.35 8.58 COPW/W2.89 2.84 2.82 Heating(air-10ºC/water35ºC)CapacityKW7.50 12.88 14.98 Heating water capacityKW2.84 4.89 5.73 Rated current A12.42 7.40 8.72 COPW/W2.64 2.63 2.61 Heating(air-15/water35ºC)CapacityKW7.12 11.98 13.88 Heating water capacityKW3.08 5.16 6.06 Rated current A13.47 7.84 9.20 COPW/W2.31 2.32 2.29 Heating(air-20/water35ºC)CapacityKW6.45 10.85 12.58 Heating water capacityKW3.19 5.37 6.22 Rated current A13.96 8.16 9.46 COPW/W2.01 2.02 2.02 Heating(air-25/water35ºC)CapacityKW6.03 9.89 11.61 Heating water capacityKW3.48 5.65 6.75 Rated current A15.22 8.58 10.25 COPW/W1.73 1.75 1.72 Heating(air+2ºC/water45ºC)CapacityKW8.05 13.80 15.48 Heating water capacityKW2.75 4.75 5.41 Rated current A12.01 7.25 8.29 COPW/W2.92 2.90 2.86 Heating(air-7ºC/water45ºC)CapacityKW7.613.10 13.85 Heating water capacityKW3.06 5.32 5.72 Rated current A13.448.12 8.75 COPW/W2.48 2.46 2.42   Heating(air7ºC/water55ºC)CapacityKW8.00 14.10 15.15 Heating water capacityKW3.05 5.40 5.87 Rated current A13.31 8.25 9.02 COPW/W2.62 2.61 2.58   Heating(air2ºC/water55ºC)CapacityKW7.95 13.24 14.05 Heating water capacityKW3.34 5.54 5.97 Rated current A14.56 8.45 9.15 COPW/W2.38 2.39 2.35   Heating(air0ºC/water55ºC)CapacityKW7.85 12.98 13.57 Heating water capacityKW3.39 5.57 5.87 Rated current A14.85 8.46 8.92 COPW/W2.31 2.33 2.31   Heating(air-5ºC/water55ºC)CapacityKW7.38 12.26 12.62 Heating water capacityKW3.63 6.06 6.31 Rated current A15.92 9.22 9.58 COPW/W2.03 2.02 2.00 Heating(air-10ºC/water55ºC)CapacityKW6.98 11.42 11.73 Heating water capacityKW3.83 6.17 6.40 Rated current A16.75 9.37 9.73 COPW/W1.82 1.85 1.83 Heating(air-15ºC/water55ºC)CapacityKW6.39 10.53 10.78 Heating water capacityKW3.73 6.12 6.34 Rated current A16.33 9.30 9.63 COPW/W1.71 1.72 1.70 Heating(air-20ºC/water55ºC)CapacityKW5.75 9.54 9.75 Heating water capacityKW3.73 6.11 6.41 Rated current A16.36 9.28 9.74 COPW/W1.54 1.56 1.52 Heating(air-25ºC/water55ºC)CapacityKW5.10 8.36 8.58 Heating water capacityKW3.77 6.23 6.54 Rated current A16.52 9.47 9.95 COPW/W1.35 1.34 1.31 Electric heating KW3000current A13.6water pumpInput (L/M/H)W 55/70/100135/190/245135/190/245Rated currentA0.24/0.30/0.430.58/0.82/1.060.58/0.82/1.06Outdoor unitDimensionmm940*375*800940*375*1340940*375*1340Net/Gross weightkg32.0 49.0 52.00 Indoor unitDimensionmm710*680*1980710*680*1980710*680*1980Net/Gross weightkg182.0 216.0 232.00 Outdoor air flow  m3/h280056005600.00 (water)flow ratem3/h1.62.63.09 Design pressure        MPa4.2/2.1Refrigerant  R32Heating water range      ºC20-55Cooling water range         ºC7-35Ambient temp    ºC-25 ºC - 43ºC-25 ºC - 43ºC-25 ºC - 43ºCNoise level(1 M)dB(A)484849Parts we are using: HEEALARX  full inverter evi air water cooling and heating heat pump adopts first class components to ensure that the unit can work in good conditions under low ambient temperature of -35 centigrade with high cop and low noise level. The key components we are using is: Full inverter twin rotary compressor from MITSUBISHI, PANASONIC or GMCC, inverter fan motor,famous brand plate heater exchanger, digital touch controller with wifi. Wide product range: HEEALARX Split type full inverter evi air water cooling and heating heat pump has wide product range capacity from 9kw, 12kw, 15kw, 18.kw and 22kw  can meet different requirement of house heating and cooling both in office and home. Advantage of HEEALARX  full DC Inverter air to water heat pump evi model Split  type: 1. Full DC Inverter technology: With Panasonic twin rotary compressor and also panasonic brushless inverter fan motor. 2. Evi Technology: Evi technology is adopte