Hikins 3013-500 Reverse Osmosis System Domestic RO Membrane

Hikins 3013-500 Reverse Osmosis System Domestic RO MembraneProduct DescriptionHikins is the largest residential RO membrane, commercial RO membrane, industrial RO membrane manufacturer in South China providing OEM service for high quality and stable performance RO membranes, With its own flat-sheet production line, Hikins has developped full range of RO membrane production for tap water, for surface water, for underground water, and for brackish water as well as sea water RO membrane.Benefits:1) Reverse Osmosis removes up to 98% of total dissolved solids.2) Hikins RO membranes deliver healthier and safer drinking water by reducing concentrations of Arsenic, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent), Copper, Turbidity, Fluoride, Lead, Radium 226/228, Selenium, and TDS.3) Hikins RO membrane is made with thicker RO membrane element, and with easier and effective rinsing and cleaning output.4) Hikisn RO membrane uses wider feed spacer which ensures the performance of the RO system.5) Hikins RO membrane is rolled on full automatic Rolling machine.SpecificationModel NO.Hikins-3013-500Active Area18.3Ft2 (1.7m2)Removal Rate96%Film Body Size305*68*68mmWater Rroduction Rate500GPDWorking Pressure80PSIPacking Quantity16PCS/CTNPacking Size320*320*360mmGross Weight9KGSDetailed Photos* "FEY" is a sub-brand of "Hikins"  Product ParametersSeriesModelActive AreaSalt RejectionWater OutputTest PrssureFt2(m2)%GPDPSI15101510-502(0.17)9750651510-753(0.25)977565ECO1812-50 9L3.5(0.35)9750651812-75 9L3.5(0.35)977565238mm1812-50 13L4(0.4)9750651812-75 13L4(0.4)9775652012-100 13L5(0.5)97100654000ppm1812-754(0.4)95751202012-804.5(0.45)96801202012-1005(0.5)96.5100120Regular1812/20122000ppm1812-50 11L4(0.4)9750651812-75 11L4(0.4)9775652012-80 12L4.5(0.45)9780652012-100 13L5(0.5)97100652012-125 13L5.2(0.52)97125652012-1506(0.6)97150652012-18010(1.0)97180652012-2007.5(0.7)9720065SeriesModelActive AreaSalt RejectionWater OutputTest PrssureFt2(m2)%GPDPSI30123012-2008.6(0.8)97200653012-25010.8(1)97250653012-30013(1.2)97300653012-40015(1.4)97400803012-60020.5(1.9)966009030133013-40015(1.4)97400803013-50018.3(1.7)96500803013-60020.5(1.9)966009032133213-60020.5(1.9)96600903213-80026(2.5)968009034133413-80028(26)96800903413-100032(3)95100090Inline RO1812-754(0.4)9750/75/10065 Installation InstructionsInstallation InstructionsUnscrew the nut on the membrane shell cover at the inlet water connection end, take out the inlet water pipe, then use the membrane shell wrench to loose the membrane shell cover. Take the RO membrane from its packaging, put the end of the membrane with 2 O-rings into the RO membrane shell (See The following Diagram ) and push it in, finally screw the membrane shell cover back on, and tighten it with membrane shell wrench, put the inlet water pipe back into the inlet water connector and screw the nut tightly, then push the membrane shell card into the large single clip.Direction For Use 1.When installing the RO membrane, you should pay attention to the direction of the membrane;2. When installing the RO membrane, you should first make sure that one end of the membrane has 2 O-rings;3. When installing, be sure to put the end with the O-ring into the end of the membrane shell with the pure water connection, for correct installation you need only a little force to put the RO membrane into the membrane shell, if you encounter too much resistance, please do not force the membrane into the shell, or it could lead to permanent damage to the membrane shell or membrane components (the membrane manufacturer does not take the responsibility for replacing components due to damage made during installation);4. Damage to the membrane shell and membrane element caused under above mentioned situation is not covered by the warranty.Company ProfileOur AdvantagesA. Full range RO membranes 50GPD to 1000GPD for home use.B. Self-produced membrane sheet.C. Each roll of membrane sheet will be tested before bulk production.D. Each finished membrane will need pass vacuum testing, to make sure salt rejection rate.E. OEM and ODM orders are welcomed.FAQFAQs on Reverse Osmosis RO membrane OEM manufacturing Q1: What type of RO membrane is avaliable in your company?A1: In general, Hikins has Domestic RO membrane and Industrial RO membrane, For Domestic RO membrane, Hikins has Municipal Tap water RO membrane, Rural Area Under Ground water RO membrane, High-flow Low pressure RO membrane, and Brackish water RO membrane. For Industrial RO membrane, Hikins has Low Pressure Engergy saving RO membrane, BW Brackish water desalination RO membrane, FR Fouling Resistant RO membrane, as well as XLE Extreme Low Pressure RO membrane, and High Salinity Brackish Water Desalination RO membrane. Q2: What is Salt Rejection Ratio?A2: The Salt rejection describes the quality of salt removed from the Reverse Osmosis feed water stream as a percentage. It's one of the key element of the RO membrane quality, however, other essential elements such as RO membrane pe