10000lph Seawater Desalination System Sea Water Reverse Osmosis System Filtration for Drinking

10000LPH Seawater Desalination system Sea Water Reverse Osmosis System filtration for drinkingIndustrial RO Seawater Desalination Plant Capacity range between 2m3/hour to 2500m3/day. If you need smaller than this capacity please see our commercial RO Desalination Machine. All RO Seawater Desalination Plants are started from booster pump, it feeds raw water to pretreatment tanks. Depends on capacity pretreatment tank size and numbers can be changed. Because of High TDS (total dissolve solid) and salt water's corrosion, we are using FRP or Carbon Steel material for pretreatment tanks. Pretreatment consists of Sand Media Filter Tank, Activated Carbon Filter Media Tank and Softener Tank which has ion exchange resin inside, they are very important for Industrial RO Desalination Machine.Product Show : Pretreatment is used to remove large number of suspended solids, iron, turbidity, unwanted color, unpleasant taste, chlorine, sediment, organic contaminants, odors. In pretreatment we can control the follow manual or automatic for Reverse Osmosis Seawater Purification Plant. After pretreatment water goes to cartridge filter housing, we call it as security filter, most of application we are using FRP or PVC Plastic material for cartridge filter housing or Bag Filter Housing. There is 1µm or 5 µm PP filter in cartridge filter housing for Reverse Osmosis Seawater Purification System. After cartridge filter housing, water goes to membrane pressure vessel with High Pressure Pump, you have brand option for High Pressure Pump (Grfos, Danfo, CNP or Chunke) and it allows you to adjust your budget. Membrane housing shell inside depends on capacity we have 4040 or 8040 Membranes. Most of our project we are using DOW Filmtec, Toray , Vontron, Hydranautics, LG brand SW RO Membranes. Seawater commercial water treatment systems Capacity range between 1.4m3/hour to 38m3/day. If you need bigger than this capacity please see our Industrial Seawater Desalination Systems. All RO Seawater membrane filtration water treatment plants are started from booster pump, it feeds raw water to pretreatment tanks. Depends on capacity pretreatment tank size and numbers can be changed. Because of High TDS (total dissolve solid) and salt water's corrosion, we are using FRP or Carbon Steel material for pretreatment tanks. Pretreatment consists of Sand Media Filter Tank, Activated Carbon Filter Media Tank and Softener Tank which has ion exchange resin inside, they are very important for commercial RO Desalination Machine. Pretreatment is used to remove large number of suspended solids, iron, turbidity, unwanted color, unpleasant taste, chlorine, sediment, organic contaminants, odors. In pretreatment we can control the follow manual or automatic for seawater commercial water treatment system.Membranes, in industrial Brackish Water Desalination Plant, are most important part. They block if parts size bigger than 0.001µm and molecular weight up to 150-250Dalton. It consists of impurities, particles, sugars, proteins, bacteria, dyes, organic and inorganic solids. Also RO Seawater Desalination Plant can have chemical dosing at pretreatment or post treatment, like antiscaling (antiscalant) , antifouling,  pH adjustment, Sterilization & Disinfection chemicals. In Chunke when we check customer water analysis report, sometimes because of scaling and fouling problems, we can use CIP (Clean In Place) System, it wash membrane in membrane housing and make membrane life longer.  Electrical Power of Industrial RO Desalination MachineFor industrial Reverse Osmosis Seawater Purification System needs 380V/50Hz/60Hz or . For bigger capacity, because of high pressure pump, it needs 380V/415V 50/60Hz. As regards to your Industrial RO Desalination Machine design, we will check your electrical supply and decide fix power to you.Function of each part of water treatment plant 1.feed water pump -- provide the pressure to quartz sand filter/active carbon filter2.Multi-medium filter-- get rid of turbidity, suspended matter, organic matter, colloid, ect.3.Active Carbon filter--Remove the color, free chloride, organic matter, harmful matter, ect. 5.Security filter--prevent large particles, bacteria, viruses into RO membrane, accuracy is 5um4.Softener--exchange "ions" of calcium and magnesium with the most common and easiest method. 6.High pressure pump-- Provide the high pressure to RO membrane 8.UV sterilizer or ozone generator--- kill bacteria7.RO system-- main part of the plant. The RO membrane's desalting rate can reach 99%, removing over 99% ions  What is a desalination system?Some water source like seawater or some underground water or some river has high level salt inside. For high level salt water has over 10000ppm salt inside. Our Industrial RO Seawater Desalination Plant remove this salt from raw water by RO (reverse osmosis) membrane system technology. Because SW RO type membranes salt recovery rate is over 99%. So, you can get accessible, usable or drinkable fresh water.