10000LPH Seawater Desalination system Sea Water Reverse Osmosis
System filtration for drinkingIndustrial RO Seawater Desalination
Plant Capacity range between 2m3/hour to 2500m3/day. If you need
smaller than this capacity please see our commercial RO
Desalination Machine. All RO Seawater Desalination Plants are
started from booster pump, it feeds raw water to pretreatment
tanks. Depends on capacity pretreatment tank size and numbers can
be changed. Because of High TDS (total dissolve solid) and salt
water's corrosion, we are using FRP or Carbon Steel material for
pretreatment tanks. Pretreatment consists of Sand Media Filter
Tank, Activated Carbon Filter Media Tank and Softener Tank which
has ion exchange resin inside, they are very important for
Industrial RO Desalination Machine.Product Show : Pretreatment
is used to remove large number of suspended solids, iron,
turbidity, unwanted color, unpleasant taste, chlorine, sediment,
organic contaminants, odors. In pretreatment we can control the
follow manual or automatic for Reverse Osmosis Seawater
Purification Plant. After pretreatment water goes to cartridge
filter housing, we call it as security filter, most of application
we are using FRP or PVC Plastic material for cartridge filter
housing or Bag Filter Housing. There is 1µm or 5 µm PP filter in
cartridge filter housing for Reverse Osmosis Seawater Purification
System. After cartridge filter housing, water goes to membrane
pressure vessel with High Pressure Pump, you have brand option for
High Pressure Pump (Grfos, Danfo, CNP or Chunke) and it allows you
to adjust your budget. Membrane housing shell inside depends on
capacity we have 4040 or 8040 Membranes. Most of our project we are
using DOW Filmtec, Toray , Vontron, Hydranautics, LG brand SW
RO Membranes. Seawater commercial water treatment systems
Capacity range between 1.4m3/hour to 38m3/day. If you need bigger
than this capacity please see our Industrial Seawater Desalination
Systems. All RO Seawater membrane filtration water treatment
plants are started from booster pump, it feeds raw water to
pretreatment tanks. Depends on capacity pretreatment tank size and
numbers can be changed. Because of High TDS (total dissolve solid)
and salt water's corrosion, we are using FRP or Carbon Steel
material for pretreatment tanks. Pretreatment consists of Sand
Media Filter Tank, Activated Carbon Filter Media Tank and Softener
Tank which has ion exchange resin inside, they are very important
for commercial RO Desalination Machine. Pretreatment is used
to remove large number of suspended solids, iron, turbidity,
unwanted color, unpleasant taste, chlorine, sediment, organic
contaminants, odors. In pretreatment we can control the follow
manual or automatic for seawater commercial water treatment
system.Membranes, in industrial Brackish Water Desalination Plant,
are most important part. They block if parts size bigger than
0.001µm and molecular weight up to 150-250Dalton. It consists of
impurities, particles, sugars, proteins, bacteria, dyes, organic
and inorganic solids. Also RO Seawater Desalination Plant can
have chemical dosing at pretreatment or post treatment, like
antiscaling (antiscalant) , antifouling, pH adjustment,
Sterilization & Disinfection chemicals. In Chunke when we
check customer water analysis report, sometimes because of scaling
and fouling problems, we can use CIP (Clean In Place) System, it
wash membrane in membrane housing and make membrane life
longer. Electrical Power of Industrial RO Desalination
MachineFor industrial Reverse Osmosis Seawater Purification System
needs 380V/50Hz/60Hz or . For bigger capacity, because of high
pressure pump, it needs 380V/415V 50/60Hz. As regards to your
Industrial RO Desalination Machine design, we will check your
electrical supply and decide fix power to you.Function of each part
of water treatment plant 1.feed water pump -- provide the
pressure to quartz sand filter/active carbon filter2.Multi-medium
filter-- get rid of turbidity, suspended matter, organic matter,
colloid, ect.3.Active Carbon filter--Remove the color, free
chloride, organic matter, harmful matter, ect. 5.Security
filter--prevent large particles, bacteria, viruses into RO
membrane, accuracy is 5um4.Softener--exchange "ions" of calcium and
magnesium with the most common and easiest method. 6.High pressure
pump-- Provide the high pressure to RO membrane 8.UV
sterilizer or ozone generator--- kill bacteria7.RO system-- main
part of the plant. The RO membrane's desalting rate can reach 99%,
removing over 99% ions What is a desalination system?Some
water source like seawater or some underground water or some river
has high level salt inside. For high level salt water has over
10000ppm salt inside. Our Industrial RO Seawater Desalination Plant
remove this salt from raw water by RO (reverse osmosis) membrane
system technology. Because SW RO type membranes salt recovery rate
is over 99%. So, you can get accessible, usable or drinkable fresh
water.
Related products about 10000lph Seawater Desalination System Sea Water Reverse Osmosis System Filtration for Drinking
- Waste Tyre Plastic Recycling Machinery Machine Tire Crusher Production Line Rubber Crumb Grinding Machine Equipment Tire Shredder
- Stretch Plastic Blowing Pet Bottle Making Blow Molding Machine Bottles Stretch Automatic Pet Bottle Blowing Machine
- Waste Plastic Pet Bottle, Water Bottle Flake, PP/HDPE/LDPE PE Film Jumbo Woven Bags Plastic Crusher Machine, Plastic Crushing Washing Recycling Machine
- Type 2 Wall-Mounted Electric Car Charging Station 7kw /11 Kwelectric Vehicle Charging Station Home Wallbox AC EV Charger Single Phase or 3three Phase
- G-View G12W Wholesale Auto Car LED Headlight Bulb High Power H13 H11 9005 H7 H4 Car LED Headlights LED Car Lights
- New Design Porcelain Round Plates Dinner Set for Wedding and Banquet
- China 2023 New Design Super Soft 100% Polyester Microfiber Knitted Oversized Decoration Hoodie Blanket
- Handmade Art Creative Materials Thickened White Paper Cup DIY Disposable Handmade Colored Paper Cup