Basic Info.Model NO.AHbS06D/IOP-AHbS18D/IOPEnergy Efficiency
GradeOneHeat Temperature50-70°CWork EnvironmentLow-temperature Heat
PumpHeat SourceAir-sourceHeating TypeCirculating
HeatApplicationVilla Family, Sauna and Swimming Pool, Hotels,
Factory Hospital, Student Apartments, Beauty Salons, Commercial,
Household, Ect.CertificationCE, ISO9001, CCC, CB, RoHS,
SASOFunctionHot Water, Air Heating, Cooling, Floor
HeatingEvaporatorBlue Hydrophilic Aluminum Finned
EvaporatorInstallationFreestandingHeating
Capacity6kw/8kw/10kw/12kw/14kw/16kw/18kwTrademarkOUTES/
OEMTransport PackageStandard Export
PackingSpecification1090mm*485mm*770mmOriginZhejiang, ChinaHS
Code8418612090Product DescriptionOUTES Solar Heat Pump System
Hybrid Water Heater for HotelSpilt EVI DC Inverter Air to Water
Heat Pump, Heating & Cooling & Hot WaterProduct DescriptionOUTES
:AHbS06D/IOP & AHbS08D/IOP &AHbS10D/IOP & AHbS12D/IOP &
AHbS14D/IOP & AHbS16D/IOP & AHbS18D/IOP Domestic Sanitary Hot
Water CoolingHeatingCooling+DHWHeating+DHWDC Inverter EVI
Compressor Workable at -25ºCAir to water heat pump split type house
heating system heat pump whole house application
diagram Product
ParametersModel AHbS06D/IOPAHbS08D/IOPAHbS10D/IOPAHbS12D/IOPAHbS14D/IOPAHbS16D/IOPAHbS18D/IOPPower
Supply/220V~240V/50Hz220V~240V/50Hz220V~240V/50Hz220V~240V/50Hz220V~240V/50Hz220V~240V/50Hz220V~240V/50HzHeating*(A7ºC/W35ºC)Max.
Heating
CapacitykW6.0 8.0 10.0 12.0 14.0 16.0 17.5 Heating
Input
PowerkW1.48 2.02 2.43 2.73 3.33 3.95 4.43 Heating
Capacity
Min./Max.kW2.4/63.2/84.2/105.0/125.4/146.4/167.17/17.5Cooling(A35ºC/W7ºC)Max.
Cooling
CapacitykW4.5 6.0 7.5 9.0 10.0 12.0 14.0 Cooling
Input
PowerkW1.48 2.32 2.90 3.05 3.50 4.60 5.76 Cooling
Capacity
Min./Max.kW1.8/4.52.4/6.03/7.53.6/94.11/105.1/125.8/14Outdoor
UnitCompressor/Twin RotaryTwin RotaryTwin RotaryTwin RotaryTwin
RotaryTwin RotaryTwin RotaryNoisedB(A)≤58≤58≤60≤58≤58≤60≤60Net
Weightkg626565127127132132Net
Dimension((L×W×H)mm1090×485×7701090×485×7701090×485×7701095×485×14101095×485×14101095×485×14101095×485×1410Packing
Dimension(L×W×H)mm1155×505×8001155×505×8001155×505×8001086×500×15401086×500×15401086×500×15401086×500×1540Indoor
UnitHeat Exchanger/PlatePlatePlatePlatePlatePlatePlateWater Pump
Brand/famous brand(optional)famous brand(optional)famous brand(optional)famous brand(optional)famous brand(optional)famous brand(optional)famous brand(optional)Rated
Water
Flowm3/h1.03 1.38 1.72 2.06 2.41 2.75 3.01 Electric
HeaterkW3333333NoisedB(A)≤35≤35≤35≤35≤35≤35≤35Net
Weightkg45454545454545Net
Dimension(L×W×H)mm1015×527×2971015×527×2971015×527×2971015×527×2971015×527×2971015×527×2971015×527×297Packing
Dimension(L×W×H)mm1210×638×4561210×638×4561210×638×4561210×638×4561210×638×4561210×638×4561210×638×456Max.
Water Outlet TemperatureºC55555555555555Range of Working
OperationºC-25~43-25~43-25~43-25~43-25~43-25~43-25~43Refrigerant/ R410A R410A R410A R410A R410A R410A R410A SCOPW/W4.0 4.05 3.9 4.07 4.05 3.95 4.26 ERP
Level (35ºC)/A++A++A++A++A++A++A++Container
Loading(20'/40'H)Sets54/16254/16254/16227/5427/5427/5427/54Remark:1.Testing
Condition:Heating*: Ambient Temp.(DB/WB):7ºC/6ºC,Water
Temp.(In/Out):30ºC/35ºC.Heating**: Ambient
Temp.(DB/WB):7ºC/6ºC,Water Temp.(In/Out):40ºC/45ºC.Cooling :
Ambient Temp.(DB/WB):35ºC/24ºC,Water Temp.(In/Out):12ºC/7ºC.2.The
above data test reference EN14825:20163.The data above is only for
reference, and might be changed without prior
notice. Detailed Photos Other
recommendations About OUTESOUTES was established in 2 0
0 6 with an industry park of 500,000m2, specializing in sales,
R&D and manufacturing air conditioner, Cooling & Heating heat
pump, Hot Water heat pump, Swimming Pool heat pump, Commercial heat
pump, Fan Coils, Air Ventilation Unit, Water Purification Equipment
and Pressure Water Tank.OUTES has reputation in domestic market.
With 2000 distributors, 1000 After-sales Service Center and 10
local warehouse. Testing Central2007,we set up the 1st testing
room, until now, we have 15 testing rooms and 30 test station. The
Testing Center is covered 5400m² (six thousand four hundred square
meters) and the total investment reach to 50,000,000(fifty million)
RMB. We have 40 engineers working here now.2019, we got the
approval from CNAS, TUV and BV. So it's more easy for us to test
the products exporting to different countries now!We can test the
performance, safety, life, noises, stress, transportation and all
the other test we need for our products. The products we can test
including Hot Water Heat Pump, Chillers, gas system Central Air
conditioners, water system Central Air Conditioners, Swimming Pool
Heat Pump, Dryers, Air Ventilation Unit and Water Purification
Unit. The test capacity from 1 Horse Power to 200 Horse Power for a
single Module Machine. The ambient test condition can be from -35ºC
to 60ºC.FAQ: Q1How about your delivery time ?A1Generally, it
will take 35 to 40 days after receiving your advance
payment. The specific delivery time depends on the items and
the quantity of
Related products about Outes Solar Heat Pump System Hybrid Water Heater for Hotel
- Waste Tyre Plastic Recycling Machinery Machine Tire Crusher Production Line Rubber Crumb Grinding Machine Equipment Tire Shredder
- Stretch Plastic Blowing Pet Bottle Making Blow Molding Machine Bottles Stretch Automatic Pet Bottle Blowing Machine
- Waste Plastic Pet Bottle, Water Bottle Flake, PP/HDPE/LDPE PE Film Jumbo Woven Bags Plastic Crusher Machine, Plastic Crushing Washing Recycling Machine
- Type 2 Wall-Mounted Electric Car Charging Station 7kw /11 Kwelectric Vehicle Charging Station Home Wallbox AC EV Charger Single Phase or 3three Phase
- G-View G12W Wholesale Auto Car LED Headlight Bulb High Power H13 H11 9005 H7 H4 Car LED Headlights LED Car Lights
- New Design Porcelain Round Plates Dinner Set for Wedding and Banquet
- China 2023 New Design Super Soft 100% Polyester Microfiber Knitted Oversized Decoration Hoodie Blanket
- Handmade Art Creative Materials Thickened White Paper Cup DIY Disposable Handmade Colored Paper Cup