High Cop 18kw Multifunctional Auto Protection Heat Pump Water Heater Chiller System

Basic Info.Energy Efficiency GradeOneHeat Temperature50-70°CWork Environment-30-27 Degree CentigradeHeat SourceAir-sourceHeating TypeMulti-power HeatApplicationVilla Family, Sauna and Swimming Pool, Hotels, Factory Hospital, Student Apartments, Beauty SalonsCertificationCE, ISO9001, CBPolyurethane Density35kg/M³Refrigerator Power120-1560WLifetime>20 YearsUse forHotels, Factory Hospital, Student Apartments, BeauTailor MadeAvaiableRefrigerantR22/R407c/R410A/R134ACapacity65-130kwApplicationsVilla Family, Hotels, Factory Hospital, Student ApHeating TypesCirculating HeatCop4.12TrademarkMuyang/ OEMTransport PackageInner Poly Bag with Outer Export Carton PackingOriginChinaHS Code84191200Product DescriptionProduct DescriptionAir energy heat pump:Energy saving The air source unit mainly absorbs heat from the air, absorbs heat from the air in winter, provides heat for heating for the room, and fully saves energy.In order to fully adapt to the load difference of the building, the selected energy output of the unit can automatically adjust the start and stop of the unit according to the water temperature of the indoor system determined by the terminal load, so that the host engine of the heat pump operates intermittently.b, reliabilityThe heating system is flexible and simple, with less investment cost, less operation cost, convenient maintenance and long service life.The main computer adopts microcomputer centralized control, which can basically eliminate the influence of misoperation on the heat pump system. Make the operation easy, convenient, reduce maintenance costs. The perfect external automatic control design of the heat pump system ensures the optimal running state and running effect of the system. C. Scientific designThe heating unit can be optimized according to the matching of load and air energy supply, the configuration of the host and indoor terminal, and all parts of the whole system, and the scheme layout is scientific and reasonable.D, the equipment adopts German Wagner ear electrostatic spraying technology, making the equipment anti-corrosion and anti-aging performance stronger.Through the perfect automatic control system (the control system has automatic and manual control functions), the system can not only realize efficient and energy saving operation, but also fully meet the maximum needs of the system. At the same time, the operation cost is the most economical and the operation condition is the most stable in stability. Fully reflect the complementarity of the unit. Efforts to achieve the overall structure of the whole system simple and reliable, simple use and maintenance, the least project investment, the highest guarantee capacity, the most economical operation cost.Model ParametersNominal cooling capacity KW/ outputInput power KW (ring 35 degrees/ Water 7 degrees)Heat production KW/ inputPower KW(ring -12ºC/ water 41ºC)Net weight KGOverall dimensions                  (Length × width × height)MYR-10ADBPG3/3P7.5KW/2.52KW6.0KW/2.3KW80KG1036×406×770mmMYR-12ADBPG3/4P8.8KW/3.1KW7.5KW/3.0KW82KG1036×406×770mmMYR-14PADBPG3/5P11.5KW/3.75KW10.0KW/3.9KW140KG1036×406×1410mmMYR-14PADBPG3/6P14KW/4.7KW12KW/4.6KW148KG1036×406×1410mmMYR-14PADBPG3/7P15.5KW/5.5KW13.5KW/5.4KW148KG1036×406×1410mmMYR-14PADBPG3/8P20.0KW/6.67KW15KW/6.0KW170KG1110×420×1560mmMYR-14PADBPG3/10P25.0KW/8.5KW20.2KW/8.08KW185KG1110×420×1560mmCompany ProfileHigh Cop 18kw Multifunctional Auto Protection Heat Pump Water Heater Chiller System this series to reach 80ºC, replace boilers and work with traditional radiator systems.The unique high-temperature heat pump is widely used for house warming. With New Times innovative & advanced technology, the high-temperature heat pump can operate very well at -15ºC ambient temperature with high output temperature, which ensures the compatibility with normal sized radiator based systems without supplementation. Compared with traditional oil/LPG boiler, Canova high-temperature heat pump produces up to 50% less CO2 whilst saves 80% running cost.heat pump delivers higher heating capacity at low evaporation temp thereby better responding to heating requirments than normal ait source heat pumps.It can supply central heating and cooling for family with fan coil units in cold area.cycle heating heat pump are designed for offering hot water for commercial use, such as office, workshop, super market, school, etc.   In order to achieve the required water temperature, large heat pump units Heating capacityKw8.915.517.6COP 4.14.14.0Heating capacityKw8.214.616.5COP 3.283.313.15Cooling capacityKw6.511.313.5EER 2.722.862.71Power supplyV/Hz220~240/50380~415/50Compressor type ScrollNumber of compressor 111Fan discharging HorizontalFan quantity 122Ambient temperatureºC-25~43Refrigerant R407CNoisedB(A)596363Dimensionmm800/400/12201110/530/12601110/530/1260Net weightKg100155165Testing condition:Heating: Ambient temp(DB/WB):7ºC/6ºC,Water temp(in/out):30ºC/35ºCHeating: Ambient temp(DB/WB):7ºC/6ºC,Water temp(in/out):40ºC/45ºC