Commercial Water-Cooled Air Conditioner Dehumidifier

Commercial Water-Cooled Air Conditioner Dehumidifier  1. Headpower Company has rich experience in design and manufacturing of refrigeration dehumidifiers. Its series of refrigeration dehumidification equipment for air dehumidification are applicable for places with need of dehumidification, such as national defense engineering, civil air defense engineering, tobacco and petrochemical industries, metro stations, aerospace, decontamination engineering, labs, telecommunication equipment rooms, archives rooms, food rooms, pharmaceutical and film workshops, and specialty glass manufacturing. 2. Headpower dehumidifiers include series of regular dehumidifiers, pipe dehumidifiers, heating pipe dehumidifiers, dehumidifiers for coastal engineering, dehumidifiers for tobacco storehouses, dehumidifiers for air-conditioning of underground engineering, full fresh air dehumidifiers, and united dehumidifiers. The dehumidifier is used to dehumidify the space, and is mainly used in places where there is a certain requirement for room humidity, such as a pharmaceutical factory, a warehouse, an electronics factory, and the like, which have strict requirements on humidity. Description: 1. Famous brand hermetic scroll compressor, Hitachi, Copeland, Sanyo,etc.  2. Package design, located on rooftop or open and level groud, save installation space, easy installation.  3. Copper tubes with aluminium fins heat exchanger, hydrophilic fins for condenser, copper fins is also available. 4. Microcomputer controller, simple interface, adjust temperature automatically, convenient for operation and easy for maintainance. 5. Galvanized steel sheet, outside powder coated, anti-corrosion and weather proof type condenser. 6. Canvas flexible duct connection, high static pressure, suitable for industrial factory. 7. Fresh air could be introduced, improve indoor air quality. 8. Hot water heating coil or electric heater could be added, heat pump type is also available 9. Refrigerant: R22, R407C, R134a  optional. Applications: Commercial buildingsSupermarkets, large-scale shopping malls, entertainment centers, high-grade hotels, theaters,restaurants, hospitals, office buildings, etc.Industry factoriesElectronic factory,pharmaceutical factory, precision instrument factory,petrochemical factory,tobacco factory, cooling for production process, etc Public PlacesAirports, stations, exhibition halls, stadiums, museums, convention centers, apartments, church,etcISO 9001, ISO14001   Water Cooled Temperature Adjustment Type DehumidifierBitmap   Items                                           Type                                                      CST8CST10CST16CST20CST25CST32CST40Dehumidity Capacitykg/h8101620253240Cooling CapacityKW1416.62833425666Voltage220V/1PH-50HZ 380V/3PH-50HZ380V/3PH-50HZProtection DevicesHigh & Low Pressure Switch,Over Load Protector,Phase Order Protection,Internal Over-heat Protector ,Frequent Boot ProtectorOperation and ControlMicrocomputer Control Automatically,Failure Warning,Trouble Self-checking, Operation Balance,Timer on/off CompressorTypeHermetic Scroll CompressorPowerKW3.754.53.75×24.5×23.75×33.75×44.5×4Heat Exchanger of Air Side Exchanger TypeCopper Tubes with Aluminum FinFan Type Ultra-low-noise CentrifugalAir Flowm3/h260032005200640078001080012800External Static PressurePa0/1000/1200/1500/180200220250Motor PowerKW0.550.750.55×20.75×22.234Heat Exchanger of Water SideTypeHigh Efficiency Shell and TubeWater Flowm3/h3.64.27.28.410.814.516.8Water ResistancemH2O2.52.52.82.82.92.93.0Connection Pipein/mmPict      /DN32 Pict          /DN32 Pict          /DN40 Pict         /DN40   2"/DN50 2"/DN50  2"/DN50Refrigerant/Volume VontrolR22/ Thermostatic Expansion ValveOperation NoisedB(A)56596263656666Weightkg220240320380450520600Dimensions(L×W×H)mm 1050×650×16501100×650×17001450×700×17001600×850×18001800×850×18002000×950×19802100×950×2050 Note:                                                                                                                                                                                                                                                                                                                     1. The above parameters are measured under the following conditions: indoor air temperatureDB27 ºC,WB21.2ºC; For air cooled type, outdoor air temperature DB35ºC,WB24ºC; For water cooled type, the inlet/outlet water temperature is 30ºC/35ºC.                                                                                                                                                                                                                               2. The specifications are subject to change without notice for improvement.                                                                                                                                                                                               3. Any special requirements please notify us in advance. /* March 10, 20