Pressure Phase Transition Electrode Boiler Hot Water Boiler 10kV
40MWThe electrode pressure phase transition boiler, can produce hot
water or steam. Its energy transition efficiency is nearly 100%,
max thermal capacity is up to 40 MW Operation principle The
electrode phase transition boiler (hot water), is a type of
electrode boiler. The phase transition happens inside the boiler to
realize heat exchange. It consists of: electrode tube, media tank,
heat exchanger, and control cabinet. The 3PH electrodes are fixed
in the electrode tubes, which are immersed into media water with
minimal conductivity. When the electricity is power on, the media
water will be directly heated. The current is transformed into
thermal, so media water is quickly gasified and function as media
steam, which will rise to heat exchanger, so the thermal is
transferred to the thermal supply water inside the heat exchanger
tube. Simultaneously, the media steam will be condensed then drop
back to media water tank. One complete process has been finished.
The media water will repeat this phase transition process:
gasification-condensation-gasification during the boiler running
time, to realize the transition from electricity into thermal. The
thermal supply power is decided by the immerse depth of electrode
into the media water, whose adjustable range: 1%-100%. Temperature
of thermal supply water(≤110ºC): electrode micro-pressure/phase
transition boiler(free from supervision and inspection);
Temperature of thermal supply water(>110ºC): electrode pressure
transition boiler. Key features1. Constant conductivity simplified
The media water is filled in one time, circulating in the closed
chamber, no contact with external. Consequently, there is no
electrochemical corrosion, hence constant conductivity can be
ensured; No needs of conductivity adjusting system, on-time
monitor. More easily operation. 2. Fixed electrode modular safe and
reliable Innovative electrode design, be made of composite
materials, precisely laser positioned. No moving parts, only a
small canned pump for adjusting media water level, super reliable.
3. Phase transition heat exchange simplified Built-in heat
exchanger, directly connected to the thermal supply system, no need
external heat exchanger. Save the cost of one-time circulation
pump, plate heat exchanger, greatly simplify the system, minimize
initial investment and floor area, much higher efficient. 4.
Thermal store system freely switch The two built-in heat exchangers
for the thermal supply or thermal store, can freely switch among:
supply thermal, store thermal, or simultaneously supply and store
thermal even without electric valve. Technical
dataModelLDR-1.42.84.25.678101214161820242940Rated thermal
supplyMW1.42.84.25.678101214161820242940High volt power
sourcekV/Hz10 kV / 50HzInput
powerMW1.42.84.25.678101214161820242940Input
currentAmp81162242323404462577693808924103911551138616742309Cable
specification &Nos of
electrodes/cablesmm25070120185240240150185240240185240300300240pc/pc36918Control
cabinet powerV/Hz380V/50HZ/25KW Temp.of
supply/backflowºC130/70ºC Thermal supply water
flowm3/h20406080100115143172200229300416572416572Pressure
dropkPa303540408080808080808080808080Connect
portDN(mm)80200250250350350400450500500500500600500600Overall
dimensionL
(mm)406047604960546056605660766076608760876087608760876087608760W
(mm)206022602460256027602760276035604060406037703770377037707540H
(mm)306032503510366038103810381038603860386064006400640064006400Shipping
weightTon4.05.25.56.97.87.98.310.516.517.223.528.631.433.567.8Operation
weightTon6.58.89.311.813.013.213.821.531.532.245.550.552.556.5128.5Note:
1,High voltage: 10kV/50Hz/3PH. Cable specification:
ZR-YJV-8.7/15-1*X(single core: X sectional area), should be ready
to be connected to boiler's electrode and prepared by client. The
boiler body should be reliably earthed (Resistance≤4Ω); 3 Phase
power source and the analog signal of zero-sequence current be
available to main control cabinet of boiler. The main control
cabinet can turn on/off the vacuum circuit break in the high volt
power source by switching signal; 2,Power of control cabinet:
380V/50Hz (3Phase-5wires); 3,the main power cable should be ready
and prepared by client; 4,The electrode boiler is a pure resistive
load, no need capacity cabinet for high volt power; 5,Max thermal
supply temp: 150ºC; 6,Adjustable thermal supply range: 5%-100%;
7,Overall dimension for reference only,varies depending on actual
project; 8,Definition of model: SBS Smart Boiler system: SBS(Smart
Boiler System)integrated boiler system (thermal supply) is a
thermal supply system, which is consisted of: electric/electrode
boiler, circulation pump system, water softener, supply pump system
(for constant pressure), control system, lighting system, alarming
system, all systems are prefabricated into a container before
delivery. The SBS is protected from wind, rain and cold. It can be
outdoor installed, and immediately started to work by simply
Related products about Pressure Phase Transition Electrode Boiler Hot Water Boiler 10kv 40MW
- Waste Tyre Plastic Recycling Machinery Machine Tire Crusher Production Line Rubber Crumb Grinding Machine Equipment Tire Shredder
- Stretch Plastic Blowing Pet Bottle Making Blow Molding Machine Bottles Stretch Automatic Pet Bottle Blowing Machine
- Waste Plastic Pet Bottle, Water Bottle Flake, PP/HDPE/LDPE PE Film Jumbo Woven Bags Plastic Crusher Machine, Plastic Crushing Washing Recycling Machine
- Type 2 Wall-Mounted Electric Car Charging Station 7kw /11 Kwelectric Vehicle Charging Station Home Wallbox AC EV Charger Single Phase or 3three Phase
- G-View G12W Wholesale Auto Car LED Headlight Bulb High Power H13 H11 9005 H7 H4 Car LED Headlights LED Car Lights
- New Design Porcelain Round Plates Dinner Set for Wedding and Banquet
- China 2023 New Design Super Soft 100% Polyester Microfiber Knitted Oversized Decoration Hoodie Blanket
- Handmade Art Creative Materials Thickened White Paper Cup DIY Disposable Handmade Colored Paper Cup