Pressure Phase Transition Electrode Boiler Hot Water Boiler 10kv 40MW

Pressure Phase Transition Electrode Boiler Hot Water Boiler 10kV 40MWThe electrode pressure phase transition boiler, can produce hot water or steam. Its energy transition efficiency is nearly 100%, max thermal capacity is up to 40 MW Operation principle The electrode phase transition boiler (hot water), is a type of electrode boiler. The phase transition happens inside the boiler to realize heat exchange. It consists of: electrode tube, media tank, heat exchanger, and control cabinet. The 3PH electrodes are fixed in the electrode tubes, which are immersed into media water with minimal conductivity. When the electricity is power on, the media water will be directly heated. The current is transformed into thermal, so media water is quickly gasified and function as media steam, which will rise to heat exchanger, so the thermal is transferred to the thermal supply water inside the heat exchanger tube. Simultaneously, the media steam will be condensed then drop back to media water tank. One complete process has been finished. The media water will repeat this phase transition process: gasification-condensation-gasification during the boiler running time, to realize the transition from electricity into thermal. The thermal supply power is decided by the immerse depth of electrode into the media water, whose adjustable range: 1%-100%. Temperature of thermal supply water(≤110ºC): electrode micro-pressure/phase transition boiler(free from supervision and inspection); Temperature of thermal supply water(>110ºC): electrode pressure transition boiler. Key features1. Constant conductivity simplified The media water is filled in one time, circulating in the closed chamber, no contact with external. Consequently, there is no electrochemical corrosion, hence constant conductivity can be ensured; No needs of conductivity adjusting system, on-time monitor. More easily operation. 2. Fixed electrode modular safe and reliable Innovative electrode design, be made of composite materials, precisely laser positioned. No moving parts, only a small canned pump for adjusting media water level, super reliable. 3. Phase transition heat exchange simplified Built-in heat exchanger, directly connected to the thermal supply system, no need external heat exchanger. Save the cost of one-time circulation pump, plate heat exchanger, greatly simplify the system, minimize initial investment and floor area, much higher efficient. 4. Thermal store system freely switch The two built-in heat exchangers for the thermal supply or thermal store, can freely switch among: supply thermal, store thermal, or simultaneously supply and store thermal even without electric valve. Technical dataModelLDR-1.42.84.25.678101214161820242940Rated thermal supplyMW1.42.84.25.678101214161820242940High volt power sourcekV/Hz10 kV / 50HzInput powerMW1.42.84.25.678101214161820242940Input currentAmp81162242323404462577693808924103911551138616742309Cable specification &Nos of electrodes/cablesmm25070120185240240150185240240185240300300240pc/pc36918Control cabinet powerV/Hz380V/50HZ/25KW Temp.of supply/backflowºC130/70ºC Thermal supply water flowm3/h20406080100115143172200229300416572416572Pressure dropkPa303540408080808080808080808080Connect portDN(mm)80200250250350350400450500500500500600500600Overall dimensionL (mm)406047604960546056605660766076608760876087608760876087608760W (mm)206022602460256027602760276035604060406037703770377037707540H (mm)306032503510366038103810381038603860386064006400640064006400Shipping weightTon4.05.25.56.97.87.98.310.516.517.223.528.631.433.567.8Operation weightTon6.58.89.311.813.013.213.821.531.532.245.550.552.556.5128.5Note: 1,High voltage: 10kV/50Hz/3PH. Cable specification: ZR-YJV-8.7/15-1*X(single core: X sectional area), should be ready to be connected to boiler's electrode and prepared by client. The boiler body should be reliably earthed (Resistance≤4Ω); 3 Phase power source and the analog signal of zero-sequence current be available to main control cabinet of boiler. The main control cabinet can turn on/off the vacuum circuit break in the high volt power source by switching signal; 2,Power of control cabinet: 380V/50Hz (3Phase-5wires); 3,the main power cable should be ready and prepared by client; 4,The electrode boiler is a pure resistive load, no need capacity cabinet for high volt power; 5,Max thermal supply temp: 150ºC; 6,Adjustable thermal supply range: 5%-100%; 7,Overall dimension for reference only,varies depending on actual project; 8,Definition of model: SBS Smart Boiler system: SBS(Smart Boiler System)integrated boiler system (thermal supply) is a thermal supply system, which is consisted of: electric/electrode boiler, circulation pump system, water softener, supply pump system (for constant pressure), control system, lighting system, alarming system, all systems are prefabricated into a container before delivery. The SBS is protected from wind, rain and cold. It can be outdoor installed, and immediately started to work by simply