Evi Copeland Low Ambient Temperature Cooling Heating Air Source Heat Pump

1.Application of Air Source Heat Pump--Eurostars EVI air source heat pumps are designed for house heating and cooling. User can change the working mode by operating the controller. Compressor starts/stops according to return water temperature. When all rooms reach preset temperature by room thermostat, heat pump will be turned off through linkage switch.--Wide Range of Applications: these EVI low temperature heat pumps could meet the heating and cooling requirements of different places, such as villas, houses, schools, factories, hotels, hospitals, spa centers, sauna centers, greenhouses, flower gardens, farms, etc. 2.Eurostars Air Source Heat Pump Features:1) Base frame and external panels are made of galvanized sheet.2) High efficiency compressor with R407C/R410A/R134A Refrigerant.3) Touch design LCD control panel, and the control signals are easier to be transferred to the control system;4) Openable cabinet door design for faster and simpler checking and maintenance5) Well heat insulation inside the unit to increase the COP. 6) Exterior rotor fan ensures lower noise and vibration7) Lovely outlook and sharp edges reduction cabinet design8) High quality copper tube coils constructed of thread technology9) Automatic defrosting function included.10) Clock & Timing on/off function.11) General testing and operational test carried out for every unit before package in the factory.12) With full protection functions including water flow, high/low pressure, phase order, over-current etc.13) Big evaporator to extract more heat from the air.14) Metal Galvanized powder coated frame15) Copeland /Panasonic compressor, green refrigerant16) Intelligent controller and Convenient LCD panel17) For low temperature area: -25ºC(optional);3. Air Source Heat Pump Technical DataAir Source Heat Pump Unit(EVI Low Ambient Temp.Type)  (Heating&Cooling)ModelESSA-05LHNESSA-05LHNESSA-05LHNESSA-05LHN2.5ES3ES4.5ES5ESWorking modeHeating&CoolingPower supply220V/50HZ380V/50HZ220V/50HZ380V/50HZHeatingAir DB/WB:7ºC/6ºC,water In/outlet:40ºC/45ºCHeating capacity (kW) 7.68.414.015.2Input power(kW) 2.322.584.384.75Current(A) 11.14.721.08.7COP(W/W)3.283.263.203.20Water flow(m3/h)1.71.93.13.4Air: -10ºC/ ,Water In/outlet:40ºC/45ºCHeating capacity (kW) 5.325.889.810.64Input power(kW) 2.202.454.164.51COP(W/W)2.412.402.362.36Air: -20ºC/   ,Water In/outlet:40ºC/45ºCHeating capacity (kW) 4.04.47.48.0Input power(kW) 2.092.333.954.29COP(W/W)1.911.891.861.86Air: -25ºC/ ,  Water In/outlet:40ºC/45ºCHeating capacity (kW) 3.94.26.47Input power(kW) 2.352.524.404.30COP(W/W)1.661.671.451.63CoolingAir DB/WB:35ºC/24ºC,water In/outlet:12ºC/7ºCCooling capacity (kW)6.87.612.613.7Input power (kW)2.392.664.514.89Current (A)11.44.821.68.9COP(W/W)2.862.842.792.80Water flow (m3/H)1.51.72.83.1       ModelESSA-10LHNESSA-10LHNESSA-10LHNESSA-15LHN5.5ES7ES2*5ES2*7ESWorking modeHeating&CoolingPower supply220V/50HZ380V/50HZ380V/50HZ380V/50HZHeatingAir DB/WB:7ºC/6ºC,water In/outlet:40ºC/45ºCHeating capacity (kW) 17.519.030.440.8Input power(kW) 5.465.949.512.75Current(A) 26.110.817.323.2COP(W/W)3.23.23.23.2Water flow(m3/h)3.94.26.89.1Air: -10ºC/ ,Water In/outlet:40ºC/45ºCHeating capacity (kW) 12.2513.321.2828.56Input power(kW) 5.195.649.0312.11COP(W/W)2.362.362.362.36Air: -20ºC/   ,Water In/outlet:40ºC/45ºCHeating capacity (kW) 9.210.016.021.4Input power(kW) 4.935.368.5711.51COP(W/W)1.861.861.861.86Air: -25ºC/ ,  Water In/outlet:40ºC/45ºCHeating capacity (kW) 7.591419Input power(kW) 5.105.808.6012.00COP(W/W)1.471.551.631.58CoolingAir DB/WB:35ºC/24ºC,water In/outlet:12ºC/7ºCCooling capacity (kW)15.817.127.436.7Input power (kW)5.626.129.7913.13Current (A)26.911.217.823.9COP(W/W)2.802.792.802.80Water flow (m3/H)3.53.86.18.2       ModelESSA-20LHNESSA-30LHNESSA-40LHN 4*5ES4*7ES4*9ES Working modeHeating&CoolingPower supply380V/50HZ380V/50HZ380V/50HZ HeatingAir DB/WB:7ºC/6ºC,water In/outlet:40ºC/45ºCHeating capacity (kW) 60.076.0115 Input power(kW) 18.723.7635.9 Current(A) 34.143.365.5 COP(W/W)3.213.203.20 Water flow(m3/h)13.417.025.7 Air: -10ºC/ ,Water In/outlet:40ºC/45ºCHeating capacity (kW) 4253.280.5 Input power(kW) 17.7722.5734.11 Current(A) 2.362.362.36 Air: -20ºC/   ,Water In/outlet:40ºC/45ºCHeating capacity (kW) 31.539.960.4 Input power(kW) 16.8821.4432.40 Current(A) 1.871.861.86 Air: -25ºC/ ,  Water In/outlet:40ºC/45ºCHeating capacity (kW) 2838  Input power(kW) 17.2024.00  Current(A) 1.631.58  CoolingAir DB/WB:35ºC/24ºC,water In/outlet:12ºC/7ºCCooling capacity (kW)54.068.4103.5 Input power (kW)19.2624.4736.98 Current (A)35.144.667.4 COP(W/W)2.802.792.80 Water flow (m3/H)12.115.323.1 4.Air Source Heat Pump Main Components Introduction1)Copeland Compressor :High quality Scroll Compressor.2)Fan: Well selected axial fan motor combined with large fan blade, which provide heavy air blow at low rotate speed, reducing vibration and noise.3)Expansion Valve: SANHUA/Danfoss Expansion valve, with more precise control of refrigerant flow system, which optimize heat pump working capacity and effi