Hot Water Heating System Ceiling Mounted Fan Coil for Villa

Hot Water Heating System Ceiling Mounted Fan Coil for Villa1. Ceiling mounted floor standing fan coil brief introductionProduct nameCeiling floor fan coilsCooling capacity2.7~12.6KWHeating capacity4.05~18.9KWDB/WB27ºC / 19.5ºCModelEST300CF2~EST1400CF2Airflow300-1400 CFMFan typeCentrifugal fanFuntionAir Conditioner Terminal UnitApplicationCommercial buildings,Hospital,Super market etc.(1)Showroom(2) Shopping mall(3) Restaurant & Bar(4) Hotels(5) Offices(6) Building(7) Clean room(8) Other fields2. Ceiling mounted floor standing fan coil unit main components(1) Fan(2) Motor(3) Casing(4) Heat exchanger(5)Water tray(6) Washable filter(7) Remote controller3. Ceiling mounted exposed floor standing fan coil features(1)Low noise operation(2)Environmental protection(3)Energy efficient(4)Diverse installation dsign(5)Clean appearance(6)Wind blowing diverse directions  4. Eurostars Fan coil unit series1Ceiling concealed fan coil unit2High ESP ducted fan coil unit3Universal concealed fan coil unit4Floor standing exposed fan coil unit5Ultra thin exposed fan coil unit6Ceiling exposed fan coil unit7Ceiling cassette fan coil unit8Ceiling exposed & floor standing fan coil unit9Wall mounted fan coil unit5. Ceiling mounted floor standing exposed fan coil unit specificationPlease ask salesman for detailed complete data or visit our website:eurostarschiller.en.made-in-china.comeurostarschiller.en.made-in-china.comCeiling Exposed/Floor Mounted Fan Coil Unit (2 pipe system)Model EST~300CF2400CF2500CF2600CF2800CF21000CF21200CF21400CF2Air flow (m3/h)High 51068085010201360170020402380Medium4205607709101210145018502150Low 3404806108201100138016002000Cooling capacityTHHW2700360045005400720090001080012600BTU921512287153591843024574307173686043004SHW19902730317442615385674681099062BTU67929317108331454318379230242767630929THMW248530303752446764997926938910605BTU848110341128061524622181270513204536195SHW15702015245030704278544766697262BTU5358687783621047814601185912276124785THLW20782504295038315660729586198989BTU70928546100681307519318248982941730679SHW12121545184423973317446053005555BTU413752736294818111321152221808918959Heating capacityHW405054006750810010800135001620018900BTU/h13823 18430 23038 27645 36860 46076 55291 64506 MW27923970494157407987105571310114011BTU/h9529 13550 16864 19591 27260 36031 44714 47820 LW17882800353339075464704887149778BTU/h6102 9556 12058 13335 18649 24055 29741 33372 Ceiling Exposed/Floor Mounted Fan Coil Unit (4 pipe system)Model EST~300CF4400CF4500CF4600CF4800CF41000CF41200CF41400CF4Air flow (m3/h)High 51068085010201360170020402380Medium4205607709101210145018502150Low 3404806108201100138016002000Cooling capacityTHHW20252700337540505400675081009450BTU69119215115191382318430230382764532253 SHW15322102244532814146519462456978BTU5229717483451119814150177272131423816THMW18642273281433504874594570427954BTU6362775896041143416635202902403427147SHW12101552188723653295419551355592BTU413052976440807211246143181752619085THLW15591878221328734245547064656742BTU532164107553980614488186692206523010SHW9331190142018452555343540814277BTU31844061484662978720117241392814597Heating capacityHW16202160270132404320540064807560BTU/h5529 7372 9219 11058 14744 18430 22116 25802 MW11151588197622963195422352405604BTU/h3805 5420 6744 7836 10905 14413 17884 19126 LW7151120141315632186281934863911BTU/h2440 3823 4823 5335 7461 9621 11898 13348 Remarks:(1)  Cooling: Inlet air temperature DB 27ºC,WB 19.5ºC; Chilled water inlet/outlet temp. 7ºC/12ºC.(2)  Heating: Inlet air temperature DB 20°C, heating water inlet/outlet temperature  60°C/50ºC.6. Ceiling floor fan coil unit construction parts7. Our fan coil production lineEvery fan coil has strict production process, including assembly, testing, packing.8. Our warranty, technical support and failure claim proceduresand (1) Warrantya. Eurostars HVAC units delivered to customers are carefully examined and tested, with 48 hours trouble-free trial operation.b. Eurostars HVAC units enjoy 1~1.5 years guarantee ever since B/L date. (2)Technical supporta. Eurostars provide full technical support and training courses after equipment installation and commissioning.b. 7*24 hours phone assistance on technical support.c.  Eurostars provide overseas guide installation,but not for free.(3)Failure claim procedures a. Detailed written failure description is required by fax or by mail, indicating the relevant equipment information and detailed description of failure.b. Relevant pictures are required for failure confirmation.c. Eurostars engineering and after-sales service team will check and form a diagnosis report.d. Further trouble-shooting solutions will be offered to customers within 24 hours after receiving the written description and pictures.9. Our OEM and ODM service:EUROSTARS was established in 2006, has a professional technical team to research and develope HVAC products. We offer OEM/ODM service to our clients.Now EUROSTARS collaborate with our clients in the following ways:(1)Produce EUROSTARS standar