Portable Multi-Parameter Patient Monitor with 12 Inch LCD Screen Price

Product DescriptionPortable Multi-Parameter Patient Monitor with 12 inch LCD Screen PricMulti Parameter Patient Monitor Features* 12.1 inch high brightness (800x600) colorful TFT LCD* Simultaneous display of 7 lead ECG waveform  * Indented menu layout to maximize the space for display        * Protection agasint defibrillation and ESU interference * New SPO2 technology to assure precise measurement            * Precise SPO2 measurement for low prefusion & finger motion                            * Analysis of real time ST segment arrhythmia* Able to analyze 15 kinds of drug level          * 168 hour graphic and tabular trend with data storage* High efficient power management without electric fan to avoid cross contamination  * Up to 66 beds for networking capacity to connect with HIS* 750 group NIBP data for recall and display Standard configuration: ECG, NIBP, SpO2, PR, RESP., TEMP., HR, Optional configuration: 1/2/4 IBP, EtCO2, multi gas, CO, 12 lead ECG, thermal recorder, touch screen, WiFi, HDMI, USB, VGA, SunTech NIBPProduct ParametersNIBPMethod: OscillometricMode: Manual, Auto, STATMeasurement Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (minutes)Measurement Period in STAT Mode: 5 minutesPulse Rate Range:40 ~ 240 bpmAlarm Type:  SYS, DIA, MEANMeasurement and Alarm RangeAdult Mode: SYS: 40 ~ 270 mmHg, DIA: 10 ~ 215 mmHg, MEAN: 20 ~ 235 mmHgPediatric Mode: SYS: 40 ~ 200 mmHg, DIA: 10 ~ 150 mmHg, MEAN: 20 ~ 165 mmHgNeonatal Mode:  SYS: 40 ~ 135 mHg, DIA: 10 ~ 100 mmHg, MEAN: 20 ~ 110 mmHgResolution: Pressure: 1mmHgAccuracy: Pressure                  Maximum Mean error: ±5 mmHg                  Maximum Standard deviation: ±8 mmHgOverpressure Protection    Adult Mode: 297 ± 3 mmHg    Pediatric Mode: 240 ± 3 mmHg    Neonatal Mode: 147 ± 3 mmHSpO2Measurement Range:  0 ~ 100 %Alarm Range: 0 ~ 100 %Resolution: 1 %Accuracy:70% ~ 100%: ±2 %, 0% ~ 69%: unspecifiedActualization interval: about 1 second Alarm Delay:  10 second Pulse Rate Measurement and Alarm Range: 0 ~ 254 bpmResolution: 1 bpmAccuracy: ± 2 bpmECGLead Mode: 5 Leads (R, L, F, N, C or RA, LA, LL, RL,V)Lead selection: I, II, III, avR, avL, avF, V, Waveform:3 channelGain:  2.5 mm/mV, 5.0 mm/mV, 10 mm/mV, 20 mm/mV, autoHR and Alarm Range: Adult: 15 ~ 300 bpm, Neo/Ped: 15 ~ 350 bpmAccuracy: ± 1% or ± 1 bpm, whichever greaterResolution: 1 bpmSensitivity:  > 200 (uVp-p) Differential Input Impedance:  > 5 MΩCMRR: Monitor: > 105 dB, Operation: > 105 dB, Diagnosis: > 85 dBElectrode offset Potential: ± 300 mVLeakage Current: < 10 uABaseline Recovery:  < 3 seconds after defibrillationECG Signal Range:±8 mV (Vp-p)Bandwidth:Surgery: 1 ~ 15 Hz, Monitor: 0.5 ~ 35 Hz, Diagnostic: 0.05 ~ 100 HzCalibration Signal:  1 (mVp-p), accuracy: ±5% ST Segment Monitoring Range: Measure and Alarm: -2.0 ~ +2.0 mVAlarm:  Available Review:  AvailableRespirationMethod:  Impedance between R-F (RA-LL)Differential Input Impedance:  >2.5 MΩMeasurement Impedance Range:  0.3~5.0 ΩBaseline Impedance Range: 0 - 2.5 KΩBandwidth:  0.3 ~ 2.5 HzResp. RateMeasurement and Alarm Range: Adult: 0 ~ 120 rpm, Neo/Ped: 0 ~ 150 rpmResolution: 1 rpmAccuracy:±2 rpmApean Alarm: 10 ~ 40 STemperatureChannel: 1Measuring and Alarm Range: 0 ~ 50 °CResolution: 0.1 °CAccuracy: ± 0.1 °CActualization interval:  about 1 secondAverage Time Constant: < 10 second Packaging & ShippingProduct dimension & weightLength×Width×Height: 312mm×287mm×175mmWeight: 3.4 KgPackage list:1* PM-200A Patient Monitor1* ECG Cable(5 Lead)1* ECG Electrodes1* SpO2 Probe1* NIBP Cuff1* Temp Probe1* Extension tube1* Power Wire1* Grounding cable 1* User manual 1* Warranty1* Certificate of QualificationPacking: 1pc/carton, size: 39*37*30cmCompany Profile /* March 10, 2023 17:59:20 */!function(){function s(e,r){var a,o={};try{e&&e.split(",").forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1