Dynamic Dr Digital Fluoroscopy with Pneumoconiosis Examination X Ray Machine with Full Body Stitching Function

Product DescriptionDigital Medical X-ray Radiographic System Multi-functional Diagnostic Dynamic DR Foinoe FN-650MA-1 Remote Table SeriesSpecificationsFN-650MA-1 PACKING LISTSystemsPartsQuantityModelDetectorDynamic Flat Panel Detector1/DXRay Diagnostic Workstation1/X-Ray SystemHigh Frequency Generator1/Control Cabinet1/X-Ray Tube1/High Voltage Cables2/Collimator1/Motion Control SystemRemote Control Table1/Remote-Control1/Mobile Remote Table(Optional)1/AccessoriesGrid1/Report Laser Printer1/Microphone/Speaker1/  FN-650MA-1 SPECIFICATIONSPartRemarkDynamic Flat Panel DetectorDynamic Flat Panel Detector Typea-Si Flat Panel DetectorScintillator Screen TypeCsl (Cesium lodide)Effective View Field17 × 17 in. (43 × 43 cm)Static Pixel Matrix3072 x 3072Dynamic Pixel Matrix1536 x 1536Spot-Film Pixel Matrix3072 x 3072Spot-Film Preparation Time≤0.8sOutput Grayscale16bitPreview Image Time≤3sMaximum Spatial Resolution3.5 lp/mmDetector Movement Range≥950mmX-ray TubeTube Focus0.6mm/1.2mmMax Output Voltage150kVHeat Capacity400kHUOutput Power40kW/100kWHigh Frequency GeneratorPower Requirement380V with 3 Phases WiresMaximum Output Power50kWOutput Voltage for Radiography40kV-150kVOutput Voltage for Fluoroscopy40kV-120kVOutput Current for Radiography10mA-650mAOutput Current for Fluoroscopy0.5mA-10mARange of mAs0.4mAs-630mAsInput Power Frequency50Hz/60HzAuto Brightness Selection Function(ABS)Remote Control TableTable Size2100mm x 880mm x 730mmTable Lateral Movement250mmSID1000-1800mmTable Rotate Range-15° - +90°Tube Column Rotate Range-35° - +35°High Voltage Cables of X-ray MachineLength: 8mRotation Angle of Foot Pedal360°One-click in Place FunctionChest Position or Table PositionRemote-Control1.One-click in Place Function:One-click to Chest Position or Table Position2.Exposure fluoroscopy switch: Exposure and fluoroscopy can be prohibited to ensure the safety of doctors and prevent accidental exposureMobile Remote Table (Optional)Height range770mm - 1170mm1.One-click in Place Function:One-click to Chest Position or Table Position2.Exposure fluoroscopy switch: Exposure and fluoroscopy can be prohibitedto ensure the safety of doctors and prevent accidental exposureGridGrid Ratio10:01Grid Focus120 cmSupport manual removalCollimator (selectable)Power150W(24VAC)Auto collimationYesTouch DisplayNo    (XS-D2)Yes    (XS-E)Inherent Filtering≤1.5mmAl@120KV    (XS-D2)≤2.0mmAl@120KV     (XS-E)Workstation (can be customized)CPUINTEL-I5RAM4GHard Disk500GDisplay1280*1024 pixels or aboveCD/DVD recording/burningSoftware1.Patient management: Manual registration, Automatic Query from Worklist2.Image acquisition: Automatic Window Adjustment, Automatic Sending,StaticImage Acquisition, Dynamic Image Acquisition,Video Save, Playback,Bone Stitching(Optional)3.Image processing: Image Correction, Image Clipping,Automatic ImageSegmentation,EAE Image Enhancement Processing , IEQ Image Processing4.Image viewer: Window/Level Adjustment, Image Flip, Image Rotation,Image Magnification, Restore5.Medical report: Automatic Loading of Patient Information, Expert Template6.Film printing: Supports Standard DICOM 3.0 Printer7.DICOM transmission: Complies with the standard DICOM 3.0 PACS andWorkstation8. Fluoroscopy amplification: 3 step : 17/15,17/12,17/9.9. Anatomically programmed radiography (APR) : auto pre-set parameter linkto the chosen body part10. Automatical collimator: After choose the body part, collimator can adjust the suitable window size, changing SID could aslo bring automaticaladjustment of collimatorDetailed Photos          Clinical Image Other Model    Company Profile    Customer Photo Good Comments from Our Clients    Send your message to us and click "Send" now /* March 10, 2023 17:59:20 */!function(){function s(e,r){var a,o={};try{e&&e.split(",").forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1