Products CharacteristicsLiquid Particle Analyzer Chemical Laser
Diffraction Particle Size Analyzer:Features: NKT5200-H is a
wet automatic laser particle sizer, which adopts the most advanced
Mie scattering principle and converging Fourier
transform optical path. High density probe and full range seamless
connection test method ensure the accuracy and repeat
ability of the test results. The operation process of nkt5100-h
is completed by computer automatically. The schematic diagram
of control system is as follows:1. Advanced optical path design:
NKT5200-H adopts the converging Fourier transform test technology
to ensure the maximum range at the shortest focal length,
effectively improving the resolution of the instrument; the unique
high-density detection unit enables 5200-H to have super small
particle testing ability, and the high-density detection unit
enables NKT5200-H to have a super full range seamless testing
ability. 2. Fully sealed fiber semiconductor laser: NKT5200-H
adopts high stability and long life fully sealed imported fiber
semiconductor laser. The excellent stability enables NKT5200-H to
have strong test repeatability, and its service life is more than
30000 hours. 3. Laser power monitoring and automatic
adjustment: the exclusive use of constant power laser, real-time
detection of laser power and automatic adjustment function,
effectively avoid the problem of laser power attenuation caused by
long-term use. At the same time, the laser power supply with
constant current, constant voltage and high filtering is adopted,
which effectively prolongs the service life of the laser and can be
used for more than 30000 hours. 4. Full automatic testing:
real automatic test, all you do is put the sample, no interference
data, no manual data selection. 5.Ultrasonic anti dry burning
function: after intensive research and development, NKT5200-H can
realize ultrasonic anti dry burning function, and avoid damaging
the ultrasonic withoutwater. 6.Adjustable ultrasonic power:
in order to meet the dispersion needs of different samples,
NKTT5200-H can adjust the ultrasonic power from 0 to 20 MW.
7. Self cleaning of circulating pipeline: the unique self-cleaning
system of circulating pipeline ensures that the pipeline is always
in the best state. 8.Sample window: unique sample window is
coated with anti reflective film. 9.Dust proof and shock
proof design: the unique suspension type guide rail fixing method
can effectively avoid the interference of external vibration to the
instrument, and make the test results more stable and reliable. The
sealing design is carried out as a whole, which greatly improves
the service life of internal components. 10. Strong
anti-corrosion design (optional): according to the actual needs of
customers, it can be equipped with acid resistance, alkali
resistance, oil resistance (including all solvent oils) and organic
solvents (such as acetone, phenol, n-hexane and other organic
solvents). 11. Automatic alignment: exclusive use of
mechanical center and optical center technology, automatic
adjustment and positioning of optical path is more accurate,
reaching micron level; at the same time, the speed of light path
adjustment is faster, and the adjustment can be completed in 15
seconds at the fastest. The self-developed automatic alignment
system consists of stepper motor, precision guide rail, precision
controller and software system. The minimum step distance is 0.2 μ
m, which ensures that the laser beam focus always passes through
the center point of the detector, and improves the accuracy and
repeatability of the test results. The automatic alignment system
is the standard configuration for all types of laser particle sizer
. 12. Unique micro circulation system: the whole dispersive
circulation system has been optimized, and the circulating test can
be carried out when the dispersing medium is larger than 120 ml,
which truly achieves the micro circulation test; the optimized
design ensures that there is no waste residue after drainage and
ensures the accuracy of the next test result. (micro test is
optional) 13. Bubble free design: the new design makes the
whole test without bubbles entering the test sample window,
avoiding bubble interference. 14. No residual sample
design: the instrument pipeline and drainage structure are
optimized, and there is no residual liquid in the instrument
pipeline and circulating pump to avoid the impact on the next test
data. 15. Sample window quick change device: the newly
designed sample window quick change device makes the sample window
replacement more convenient and fast. 16. Dew point
measurement: fogging in the sample window will affect the accuracy
of measurement. Such test results have no practical significance.
NKT5200-H is equipped with a fogging point
measurement system, and the software will automatically
prompt once fogging occurs.Product Parameters
Specifications:Measuring principle:full range laser diff
Related products about Liquid Particle Analyzer Chemical Laser Diffraction Particle Size Analyzer
- Waste Tyre Plastic Recycling Machinery Machine Tire Crusher Production Line Rubber Crumb Grinding Machine Equipment Tire Shredder
- Stretch Plastic Blowing Pet Bottle Making Blow Molding Machine Bottles Stretch Automatic Pet Bottle Blowing Machine
- Waste Plastic Pet Bottle, Water Bottle Flake, PP/HDPE/LDPE PE Film Jumbo Woven Bags Plastic Crusher Machine, Plastic Crushing Washing Recycling Machine
- Type 2 Wall-Mounted Electric Car Charging Station 7kw /11 Kwelectric Vehicle Charging Station Home Wallbox AC EV Charger Single Phase or 3three Phase
- G-View G12W Wholesale Auto Car LED Headlight Bulb High Power H13 H11 9005 H7 H4 Car LED Headlights LED Car Lights
- New Design Porcelain Round Plates Dinner Set for Wedding and Banquet
- China 2023 New Design Super Soft 100% Polyester Microfiber Knitted Oversized Decoration Hoodie Blanket
- Handmade Art Creative Materials Thickened White Paper Cup DIY Disposable Handmade Colored Paper Cup