High Performance Power Cable Accessory 33kv Heat Shrinkable Indoor Termination

4E-NRS, 4E-WRS, 4E-JRS Heat Shrinkable Cable Accessories4E-NRS, 4E-WRS, 4E-JRS heat shrinkable cable accessories is applied to 35kV and below rubber cable. Heat shrinkable cable accessories is using import multi-phase polymer, it's the update products of wrapped type cable accessories. With convenient installation, keep on suitable radial pressure on the cable body, interface characteristic is good. the parameter type stress control tube to improve the distribution of the electric field, which can effectively solve the cable outer shield section in electric stress concentration problem. The electrical properties are improved from wrapped type cable accessories to ensure the safety and reliable operation. The main components are tubular, basically including stress tube, insulation tube, three fingered tube, sealed tube protective sleeve, etc    Main performance and structure features:Technical performance: meet BS EN 50181, IEC60502, GB/T12706 requirements.Heat shrinkable raw materials: stress tube is parameter type, well-distributed electric field at the insulating cable cut off place. Insulating tube has insulation effect, protective sleeve has protection effect. Product heat shrinkable is quite stable, can shrinkable to the original size in heating condition, the residual deformation is small. All the products are processing forming in the factory. There's no need to use fire, no special training, installation is simple and fast. It has resistance to filth, aging, and good waterproof, with superior cold heat resistant performance.Surface is smooth and beautiful. Heat shrinkable outdoor termination1. Lug  2. Cable core  3.  Melt adhesive  4. Sealing tube  5. Cable insulation layer  6. Heat shrinkable tube  7. Single hole rain skirt  8. Stress tube  9. Cable semi-conductive layer  10. Copper copper screen layer  11. Three hole rain skirt  12. Three fingered tube  13. Earthing wire  14. Cable  15. Triangulation cone  VoltageSection number12348.7/1525-5070-120150-240300-40012/20, 26/3550-95120-185240-400500-630Heat shrinkable indoor termination1. Lug  2. Cable core  3.  Melt adhesive  4. Sealing tube  5. Cable insulation layer  6. Heat shrinkable tube  7. Single hole rain skirt  8. Stress tube  9. Cable semi-conductive layer  10. Copper copper screen layer  11. Three hole rain skirt  12. Trigeminal sheath  13. Earthing wire  14. Cable  15. Triangulation cone  VoltageSection number12348.7/1525-5070-120150-240300-40012/20, 26/3550-95120-185240-400500-630Heat shrinkable middle joint 1. Semi conductive tape  2. Waterproof sealant adhesive  3. Semi conductive tube  4. Cable insulation  5. Connecting tube  6. Semi conductive tape  7. Semi conductive layer  8. Outer insulation tube  9. Inner insulating tube  10. Stress tube 11. Copper screen tape  VoltageSection number12348.7/1525-5070-120150-240300-40012/20, 26/3550-95120-185240-400500-630Heat shrinkable indoor, outdoor termination, and joint electrical performance parametersItemRequirement8.7/15 (17.5)12/20 (24)26/35 (40.5)5min Power frequency voltage test39kV, no flashover, no breakdown54kV, no flashover, no breakdown117kV, no flashover, no breakdownPartial discharge test15kV discharge capacity≤10pC20kV discharge capacity≤10pC45kV discharge capacity≤10pCLightning impulse test95kV125kV200kV10 times of positive and negative, no flashover, no breakdownConstant voltage load cycle test in air22kV30kV65kVThe conductor is heated to 95-100ºC, each cycle is 8h, heating 5h and cooling 3H for 60 cycles.Partial discharge test at high temperature15kV discharge capacity≤10pC20kV discharge capacity≤10pC45kV discharge capacity≤10pC15min AC voltage withstand test22kV, no flashover, no breakdown30kV, no flashover, no breakdown65kV, no flashover, no breakdownNegative DC voltage test52kV, no flashover, no breakdown64kV, no flashover, no breakdown156kV, no flashover, no breakdown4H power frequency voltage test35kV, no flashover, no breakdown48kV, no flashover, no breakdown104kV, no flashover, no breakdownOutdoor termination salt spray test 1000h11kV, no flashover, no breakdown15kV, no flashover, no breakdown32.5kV, no flashover, no breakdownIndoor termination humidity test 300h11kV, no flashover, no breakdown15kV, no flashover, no breakdown32.5kV, no flashover, no breakdown/* March 10, 2023 17:59:20 */!function(){function s(e,r){var a,o={};try{e&&e.split(",").forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1