Singclean High Viscoelastisity Ophthalmic Viscoelastic Device Solution Hyaluronic Acid Gel for Eye Surgery

Singclean High viscoelastisity Ophthalmic Viscoelastic Device Solution Hyaluronic Acid Gel for Eye SurgeryKey Words: Hyaluronic Acid, dermal filler, facial hyaluronate acid, cosmetic products, plastic surgery, high quality, good effect, Anti Aging, Nasolabial folds, lip fillerProduct Description  1.Introduction        1).Can prevent the tissue being damaged from surgical instrument through shock absorption and cell layer lubrication;       2).High viscoelastisity can maintain good surgery space';       3).High purity and high transparencr can mainain the good view for surgery operation       4). No need for cold storage.2.Application:1).Cataract extraction surgery2).Cataract ultrasonic phacoemulsifiation3).Corneal transplant surgery4).Glaucoma surgery5).Retinal detachment 6).Intraocular lens implantation 7).Removal, iridectomy, trabeculectomy, ocular trama surgery 8).Ophthelmic surgery and other surgery9).Lubricating and protecting against UV Light10).Protection of dry corneas 3.specificationModle No.VolumeConcentrationPackingSC-15-1.01.0ml15mg/mlprefilledsyringein blisterUsage and dosage:A Cataract extraction surgery,IOL implantation:0.20~0.75ml into anterior chamber,0.1ml on the  IOL spreading.B Cataract surgery: 0.1~0.5ml injection into anterior chamber.C IOL implantation:before implantation 0.1~0.5ml injection into anterior chamber,0.1ml on the  IOL spreading.D Corneal transplant surgery:after removal of corneal,0.1~0.5ml injection into anterior chamber,after transplant of corneal spreading around 0.1ml. Characteristic  1. Highest Concentration (20mg/ml) domestic viscoelastic solution2. Viscoelastic solution,no need for cold storage3. Super high molecule weight 2.2 Mil.-4 Mil.Dalton,exceed the  professional standard (0.8Mil.Dalton) 3-5 times,is,the,guarantee basis of pseudoplasticity,viscocity,elasticity, cohesiveness and paintability.Product advantages:      1. Non-animal source           2. Good biocompatibility          3. High viscoelasticity          4. High lubricity            5. High physical alterabilityScope of application:Used as ophthalmic viscoelastic device.1).Cataract extraction surgery                                   2).Cataract ultrasonic phacoemulsifiation3).Corneal transplant surgery                                   4).Glaucoma surgery5).Retinal detachment                                             6).Intraocular lens implantation 7).Removal, iridectomy, trabeculectomy, ocular trama surgery       8).Ophthelmic surgery and other surgeryMain ProductsCompany Profile   /* March 10, 2023 17:59:20 */!function(){function s(e,r){var a,o={};try{e&&e.split(",").forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1