Electrical cUL Certificate Nmd90 14/2 12/2 14/3 12/3 Indoor Cable Non-Metallic Solid Conductor with Ground Wire 300V Canada Market Household Electrical Wires

NM-B Wire , THHN Core PVC sheath 600v , UL listed mass production, factory price  UL no. E487898Applications:Type NM-B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC). Type NM-B cable is commonly used for residential fixtures, switches, and loads rated for at least 90ºC. Type NM-B ampacity limitation shall be in accordance with the 60ºC conductor temperature rating, as specified in the National Electrical Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations. Type NM-B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness.Standards:Underwriters Laboratories Standards UL-83, UL-719Federal Specification A-A-59544ASTM-B3 and B8ARRA 2009; Section 1605 "Buy American" CompliantCONSTRUCTION:Conductors:Solid 14-10 AWG soft, uncoated copper, per ASTM-B3Stranded 8 AWG conductor and larger uncoated, copper ASTM-B8Insulation:Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90°C in dry locations.Grounding Conductor:Soft, uncoated copper per ASTM-B3 and/or ASTM-B8Jacket:A 30-mil, color-coded, PVC jacket is applied over the completed assembly as follows:14 AWG White I 12 AWG Yellow I 10 AWG Orange I 8 AWG Black I 6 AWG BlackAssembly:2-conductor construction has the insulated conductors laid parallel with a bare copper ground wire wrapped in paper and laid parallel between the insulated conductors. The entire assembly is wrapped with a paper separator before applying the PVC outer jacket. SuperSlick Elite is available in sizes: 14 AWG, 12 AWG, 10 AWG constructions. 3 and 4 conductor constructions may have the insulated conductors laid parallel or twisted together before applying the PVC outer jacket. Specification:Size (AWG)Number of StrandsGround  Wire  SizeInsulationThickness(in)Allowable Ampacity(Amps)*Outside Diameter(in)Approximate Net Weight(lbs/1000 ft)PVCNylon 14/2 G  Solid  14  0.015  0.004  15  0.170 x 0.390  56  12/2 G  Solid  12  0.015  0.004  20  0.160 x 0.450  82  10/2 G  Solid  10  0.020  0.004  30  0.210 x 0.493  123  8/2 G  7  10  0.030  0.005  40  0.290 x 0.580  185  6/2 G  7  10  0.030  0.005  55  0.330 x 0.695  256  14/3 G  Solid  14  0.015  0.004  15  0.170 x 0.450  74  12/3 G  Solid  12  0.015  0.004  20  0.345  107  10/3 G  Solid  10  0.020  0.004  30  0.430  165  8/3 G  7  10  0.030  0.005  40  0.555  251  6/3 G  7  10  0.030  0.005  55  0.612  352  4/3 G  7  8  0.040  0.006  70  0.820  565  2/3 G  7  8  0.040  0.006  95  0.945  841  **14/4 G & 14/2-2 G  Solid  14  0.015  0.004  12  0.345  90  **12/4 G & 12/2-2 G  Solid  12  0.015  0.004  16  0.385  132  **10/4 G  Solid  10  0.020  0.004  30  0.540  205